Adiabatic Flame Temperature Calculator
Find the upper-limit flame temperature of a fuel and air mixture from an energy balance, and see how it changes from lean to rich.
🔥 What is the Adiabatic Flame Temperature?
The adiabatic flame temperature is the temperature that the products of a combustion reaction would reach if every joule of released chemical energy went into heating them. Nothing escapes as radiation, nothing leaks through walls, and no work is done on the surroundings. It is therefore the ceiling for the temperature of a real flame burning the same mixture at constant pressure, and it is the first number engineers ask for when they size a furnace, a gas turbine combustor or a burner.
The idea is used in many places. A boiler designer compares the flame temperature of natural gas with the metal limits of the tubes. A turbine engineer dilutes the mixture with extra air so the flame does not exceed what the first blade row can survive. A safety engineer uses the temperature rise to judge how violent a leak ignition could be. A student uses the same energy balance to see why hydrogen burns hotter than lean methane, and why preheated air raises the temperature of an industrial furnace.
It helps to be clear about what the number is not. It is not the temperature of a real flame, which is lower because of radiation, heat loss and dissociation of CO2 and H2O at high temperature. It is also not the same as the temperature of a rocket chamber: this page assumes fuel burning in air near one atmosphere with constant mean heat capacities, while the rocket chamber conditions calculator handles propellant pairs at high pressure for nozzle work.
This calculator uses a deliberately simple energy balance. You pick a fuel, an equivalence ratio and the inlet temperature of the reactants, and it returns the flame temperature, the heat released, the product composition and a chart of flame temperature against equivalence ratio across lean and rich mixtures. The fuel properties and mean heat capacities are rounded and approximate, so the output is a teaching estimate rather than a design value.
📐 Formula
📖 How to Use This Calculator
Three steps
💡 Example Calculations
Example 1 - Stoichiometric methane in air
Methane, phi = 1, inlet 298.15 K
Example 2 - Lean hydrogen flame
Hydrogen, phi = 0.5, inlet 298.15 K
Example 3 - Rich propane with preheated air
Propane, phi = 1.2, inlet 500 K
Example 4 - Lean methane at phi = 0.6
Methane, phi = 0.6, inlet 298.15 K
❓ Frequently Asked Questions
📚 Sources and Notes
The definition and the idea of an upper-bound flame temperature follow the Wikipedia article on adiabatic flame temperature. The heating values, mean heat capacities, air composition and CO combustion heat in this tool are rounded, approximate and illustrative; they were not taken from a single tabulated source and should not be used for design.
See also the heat of combustion calculator, the standard enthalpy of formation calculator and the Kirchhoff law calculator.
🔗 Related Calculators
What is the adiabatic flame temperature?
It is the temperature the combustion products reach if all the heat released by burning raises their temperature, with no heat lost to the surroundings and no work done. It is an upper bound, because real flames lose energy by radiation and conduction and by dissociation of the products.
How do you calculate the adiabatic flame temperature?
Write an energy balance: the heat released by the reaction plus the sensible heat of the reactants equals the sensible heat of the products. With a mean product heat capacity, Tad = 298.15 + (Q + Cp,react (T0 - 298.15)) / Cp,prod. For methane at phi = 1 this tool gives about 2,362 K.
What is the adiabatic flame temperature of methane in air?
With the simple model on this page, a stoichiometric methane and air mixture at 298.15 K reaches about 2,362 K (2,089 C). Detailed equilibrium calculations that include dissociation give a noticeably lower value, so treat the simple result as an upper estimate.
What is the equivalence ratio?
The equivalence ratio phi is the actual fuel to oxidiser ratio divided by the stoichiometric fuel to oxidiser ratio. Phi below 1 means excess air (lean), phi equal to 1 is stoichiometric, and phi above 1 means excess fuel (rich).
Why does the flame temperature peak near phi = 1?
At phi below 1 the same heat is shared among extra unreacted air, which lowers the temperature. At phi above 1 some fuel cannot burn completely, so less heat is released and the temperature falls again. The maximum sits close to stoichiometric.
Why are real flame temperatures lower than the calculated value?
At high temperature CO2 and H2O partly dissociate into CO, H2, OH and other species, which absorbs energy. Real flames also lose heat by radiation and conduction. This tool ignores dissociation and uses constant mean heat capacities, so it gives a high estimate.
How does preheating the air change the flame temperature?
Preheating adds sensible heat to the reactants, so the products end up hotter. Because the products have a larger total heat capacity than the incoming air, the rise in flame temperature is smaller than the rise in inlet temperature.
How is this different from the rocket chamber temperature calculator?
This page models fuel burning in air at about one atmosphere with a simple constant-heat-capacity energy balance. The rocket chamber page deals with propellant pairs at high pressure, where the oxidiser is not air and the performance numbers feed nozzle calculations.
Which heating value does the calculator use?
It uses the lower heating value, where the water in the products stays as vapour. For methane that is 802.3 kJ per mole, compared with 890.3 kJ per mole for the higher heating value that assumes the water condenses.
What happens when the mixture is too rich?
For rich mixtures the tool lets hydrogen burn first and then splits the remaining carbon between CO2 and CO. When there is not enough oxygen even for CO it reports that the mixture is outside the simple model instead of returning an unreliable number.