Eyring Equation Calculator
Calculate a transition-state rate constant and half-life from the activation enthalpy and entropy, or work backward to dG‡, dH‡ and dS‡.
⚡ What is the Eyring Equation?
The Eyring equation is the central result of transition state theory. It says that a reaction proceeds by passing through a high-energy arrangement of atoms, the activated complex, and that the rate constant equals the frequency kB T / h at which complexes cross the barrier, multiplied by the equilibrium probability of finding the complex. That probability is exp(−dG‡/RT), where dG‡ = dH‡ − T dS‡ is the Gibbs free energy of activation. Splitting dG‡ into an enthalpy and an entropy gives the full form k = (kB T / h) exp(dS‡/R) exp(−dH‡/RT).
It is used throughout kinetics. Organic chemists report dH‡ and dS‡ to diagnose mechanisms, since a large negative dS‡ points to an associative step. Biochemists use it for enzyme turnover and for protein unfolding, where barrier heights of 70 to 100 kJ/mol give half-lives from seconds to hours. Materials scientists apply it to diffusion and creep, and pharmaceutical scientists use it to judge degradation rates and shelf life from short high-temperature experiments.
The Eyring equation is often confused with the Arrhenius equation. The two look similar because both give a rate that increases exponentially with temperature, but Arrhenius is an empirical fit with a constant prefactor A, while Eyring has a theoretical prefactor kB T / h that grows with temperature and separates enthalpic and entropic contributions. A second misconception is that dG‡ is the same as the reaction free energy. It is not: it measures the barrier, not the thermodynamic driving force, so it controls speed and not where equilibrium lies.
This calculator has three modes. The first computes k, dG‡ and the first-order half-life from dH‡, dS‡, T and an optional transmission coefficient. The second inverts the equation to find dG‡ from a measured k. The third fits dH‡ and dS‡ from rate constants at two temperatures, which is the two-point version of the Eyring plot. Each mode draws a chart so you can see how sensitive the rate is to the barrier and to temperature.
📐 Formula
📖 How to Use This Calculator
Three modes
💡 Example Calculations
Example 1 - A moderately fast reaction at room temperature
dH‡ = 50 kJ/mol, dS‡ = -50 J/(mol K) (illustrative), T = 298.15 K, kappa = 1
Example 2 - A slow reaction with a high barrier
dH‡ = 100 kJ/mol, dS‡ = 0 J/(mol K) (illustrative), T = 298.15 K
Example 3 - Free energy of activation from a measured rate
k = 1.0e-3 s^-1 at T = 310 K
Example 4 - Activation parameters from two temperatures
k1 = 0.001 s^-1 at 298.15 K and k2 = 0.015 s^-1 at 318.15 K (illustrative)
❓ Frequently Asked Questions
📚 Sources and Notes
The rate expression and its assumptions follow the Wikipedia article on the Eyring equation and the Wikipedia article on transition state theory. The activation parameters and rate constants in the examples are illustrative values chosen for demonstration, not measured data for any specific reaction.
See also the Arrhenius equation calculator, the activation energy calculator and the Gibbs free energy of reaction calculator.
🔗 Related Calculators
What is the Eyring equation?
The Eyring equation, from transition state theory, gives a rate constant as k = kappa (kB T / h) exp(dS‡/R) exp(-dH‡/RT), or equivalently k = kappa (kB T / h) exp(-dG‡/RT). It links the speed of a reaction to the enthalpy and entropy of activation of its transition state.
How do you calculate a rate constant from dH‡ and dS‡?
Compute dG‡ = dH‡ - T dS‡, then k = kappa (kB T / h) exp(-dG‡ / RT). For dH‡ = 50 kJ/mol, dS‡ = -50 J/(mol K) and T = 298.15 K, dG‡ = 64.91 kJ/mol and k = 26.42 s^-1.
What is the difference between the Eyring and Arrhenius equations?
Arrhenius is empirical, k = A exp(-Ea/RT). Eyring comes from statistical mechanics and splits the barrier into dH‡ and dS‡, with a built-in prefactor kB T / h that grows linearly with temperature. For a solution reaction, Ea is about dH‡ + RT.
What is kB T / h?
It is the universal frequency factor of transition state theory, about 6.21 x 10^12 s^-1 at 298.15 K. It is the maximum rate at which a barrierless crossing of the transition state could proceed. The actual k is this value multiplied by exp(-dG‡/RT), which is always smaller than one.
How do you find the half-life from the Eyring equation?
For a first-order process, t1/2 = ln 2 / k. With dH‡ = 100 kJ/mol and dS‡ = 0 at 298.15 K, k = 1.879e-5 s^-1 and t1/2 = 10.24 h. Remember that the formula is only valid for unimolecular or pseudo-first-order steps.
How do you find dG‡ from a measured rate constant?
Invert the equation: dG‡ = RT ln(kB T / (h k)) taking kappa = 1. For k = 1.0 x 10^-3 s^-1 at 310 K, dG‡ = 93.83 kJ/mol, which is 22.43 kcal/mol.
How do I get dH‡ and dS‡ from experiments?
Measure k at several temperatures and plot ln(k/T) against 1/T, the Eyring plot. The slope is -dH‡/R and the intercept is ln(kB/h) + dS‡/R. Two temperatures give a rough estimate, and more points let you check linearity.
What does a negative activation entropy mean?
A negative dS‡ means the transition state is more ordered than the reactants, as in an associative step where two molecules must come together in a specific orientation. A positive dS‡ suggests a looser transition state, as in a dissociative step.
What is the transmission coefficient kappa?
Kappa is the fraction of transition-state crossings that lead to products. Transition state theory takes it as 1, assuming no recrossing. In practice it can be smaller, for example in viscous solvents or when the reaction coordinate is imperfect, so it scales k directly.
How does the rate change with temperature in the Eyring equation?
Through the prefactor T, which rises linearly, and through the exponential, which dominates. Around room temperature, a barrier of 75 kJ/mol roughly doubles or triples the rate for each 10 K of warming, which is the familiar rule of thumb.
Which assumptions are built into this calculator?
It assumes transition state theory holds, dH‡ and dS‡ do not change with temperature, the step is first order for the half-life, and kappa is as entered (1 by default). Gas-phase bimolecular steps need pressure-based standard states that are not handled here.