WLF Equation Viscosity-Temperature Calculator

Find how viscosity and relaxation time change with temperature above the glass transition using the Williams-Landel-Ferry shift factor.

📈 WLF Equation Viscosity-Temperature Calculator
Reference temperature (Tg)
K
Temperature (T)
K
C1
C2
K
Viscosity at Tg (illustrative)
Pa·s
Relaxation time at Tg (illustrative)
s
Arrhenius activation energy (Ea)
kJ/mol
log10 aT
—
Shift factor aT
—
Viscosity η(T)
—
log10 η
—
Relaxation time τ(T)
—
T minus Tref
—

WLF shift factor
—
Arrhenius shift factor
—
WLF log10 aT
—
Arrhenius log10 aT
—
WLF / Arrhenius
—
Apparent Ea of WLF at T
—

📈 What is the WLF Equation?

The Williams-Landel-Ferry (WLF) equation describes how fast a polymer or other glass-forming liquid slows down as it is cooled toward its glass transition. It was proposed by Malcolm Williams, Robert Landel and John Ferry in 1955 and is the standard way of expressing the shift factor in time-temperature superposition. The shift factor aT is the multiplier that converts a time scale measured at a reference temperature into the time scale at another temperature. Because viscosity and relaxation time both follow the same shift, one number lets you predict how a melt flows, how a rubber relaxes, or how long a creep test must run at a different temperature.

The equation reads log10 aT = −C1 (T − Tref) / (C2 + T − Tref). When the reference temperature is the glass transition temperature Tg, many polymers give approximately C1 = 17.44 and C2 = 51.6 K, the so-called universal constants. They imply that the viscosity falls by about 4.9 decades in just 20 K above Tg, which is why a polymer processed only a little above Tg is so much more fluid. Materials scientists use the equation to build master curves from short measurements at several temperatures, to estimate processing viscosities for injection moulding or extrusion, to compare annealing and ageing times, and to design measurement programmes that would otherwise take months.

Three cautions apply. The constants are empirical and valid over a limited window above Tg: the IUPAC definition quotes roughly Tg to Tg + 50 K, and practical use extends to about Tg + 100 K before the Arrhenius form usually does better. The equation does not describe the glassy state, and it diverges mathematically at T = Tref − C2. And the universal constants are only typical; real polymers show variations, so fitted constants should be used for accurate work. A related misconception is that temperature dependence is always Arrhenius. Near Tg the apparent activation energy is several hundred kJ/mol and falls fast as temperature rises, which is the signature of free-volume-like WLF behaviour.

This calculator offers two modes. Shift and viscosity computes log aT, aT, the viscosity and the relaxation time from reference values at Tg and draws log viscosity against temperature. Arrhenius comparison sets a WLF shift factor beside an Arrhenius one with the same reference temperature, reports the apparent activation energy of the WLF law at your temperature, and plots both. For the thermal transition itself use the Fox equation estimator.

📐 Formula

log10 aT  =  −C1 (T − Tref) ÷ (C2 + T − Tref)
aT = shift factor (dimensionless)
T = temperature of interest (K); Tref = reference temperature, here Tg (K)
C1, C2 = WLF constants; universal values 17.44 and 51.6 K when Tref = Tg
Viscosity: η(T) = ηref aT; relaxation time: τ(T) = τref aT
Example: T = 393 K, Tref = 373 K gives log10 aT = −17.44 × 20 / 71.6 = −4.872
log10 aT (Arrhenius)  =  (Ea / (R ln 10)) (1/T − 1/Tref)
Ea = activation energy (J/mol), R = 8.314 J/(mol K)
Apparent Ea of WLF: R T2 ln 10 × C1 C2 / (C2 + T − Tref)2
Example: at T = Tref = 373 K the WLF law corresponds to 900.3 kJ/mol

📖 How to Use This Calculator

Shift factor and viscosity

1
Enter the reference temperature and constants - Type the glass transition temperature in kelvin as the reference, and keep the universal constants C1 = 17.44 and C2 = 51.6 K or enter your own fitted values.
2
Choose the temperature and a comparison - Enter the temperature of interest. Use Shift and viscosity mode with reference viscosity and relaxation time, or Arrhenius comparison with an activation energy.
3
Read the shift factor and the chart - Read log10 aT, the viscosity and relaxation time, and check the range note and the chart for how steeply the property changes with temperature.
4
Restore the defaults - Use the reset button to return to the universal constants after trying fitted values.

💡 Example Calculations

Example 1 - 20 K above Tg with universal constants

Tref = 373 K, T = 393 K, C1 = 17.44, C2 = 51.6 K, reference viscosity 1e12 Pa s (illustrative)

1
log aT = −17.44 × 20 / (51.6 + 20) = −348.8 / 71.6 = −4.872.
2
aT = 10−4.872 = 1.344e-5.
3
Viscosity = 1e12 × 1.344e-5 = 1.344e+7 Pa s (log10 = 7.128), and a 100 s relaxation time becomes 0.0013 s.
log10 aT = −4.872, η = 1.344e+7 Pa s
Try this example →

Example 2 - 50 K above Tg

Tref = 373 K, T = 423 K, universal constants

1
log aT = −17.44 × 50 / (51.6 + 50) = −872 / 101.6 = −8.583.
2
aT = 2.614e-9, so the viscosity falls from 1e12 Pa s to 2,614.1 Pa s (log10 = 3.417).
3
The relaxation time drops from 100 s to 2.614e-7 s. T minus Tref is 50.0 K, at the upper end of the IUPAC range.
log10 aT = −8.583, η = 2,614.1 Pa s
Try this example →

Example 3 - WLF against an Arrhenius law

Tref = 373 K, T = 393 K, Arrhenius Ea = 200 kJ/mol (illustrative)

1
WLF: log aT = −4.872, so aT = 1.344e-5.
2
Arrhenius: log aT = (200,000 / (8.3145 × 2.3026)) (1/393 − 1/373) = −1.425, so aT = 0.0376.
3
The WLF shift is 3.579e-4 times the Arrhenius one. The apparent activation energy of the WLF law at 393 K is 519.0 kJ/mol, so a constant 200 kJ/mol cannot follow it.
WLF = 1.344e-5, Arrhenius = 0.0376, apparent Ea = 519.0 kJ/mol
Try this example →

Example 4 - Fitted constants at a lower reference temperature

Tref = 298 K, T = 318 K, C1 = 16.6, C2 = 104 K, reference viscosity 1e5 Pa s, relaxation time 1 s (all illustrative)

1
log aT = −16.6 × 20 / (104 + 20) = −332 / 124 = −2.677.
2
aT = 10−2.677 = 0.0021.
3
Viscosity = 1e5 × 0.0021 = 210.2 Pa s (log10 = 2.323), and the relaxation time is 0.0021 s. Constants fitted at a different reference temperature give a much milder temperature dependence.
log10 aT = −2.677, η = 210.2 Pa s
Try this example →

❓ Frequently Asked Questions

What is the WLF equation?+
The Williams-Landel-Ferry equation is an empirical formula for the shift factor in time-temperature superposition: log10 aT = -C1 (T - Tref) / (C2 + T - Tref). It describes how the time scale, and so viscosity and relaxation time, of a polymer changes with temperature above its glass transition.
What are the universal WLF constants?+
When the reference temperature is Tg, the commonly quoted universal constants are C1 = 17.44 and C2 = 51.6 K. Constants for a particular polymer, or for a different reference temperature, differ and should be taken from fitted data.
How do you calculate viscosity from the WLF equation?+
Find aT = 10^(log10 aT), then eta(T) = eta_ref x aT. At T = Tg + 20 K with universal constants, log10 aT = -17.44 x 20 / 71.6 = -4.872, aT = 1.344e-5, so a reference viscosity of 1e12 Pa s becomes 1.344e7 Pa s.
What temperature range is the WLF equation valid for?+
It is intended for temperatures from Tg to roughly Tg + 100 K. The IUPAC Gold Book describes the constants as valid over a limited range of about Tg to Tg + 50 K. Below Tg it fails, and far above Tg the Arrhenius form usually fits better.
What does the shift factor aT mean?+
aT is the factor by which time scales shift when temperature changes from Tref to T. Relaxation times and viscosities at T equal their values at Tref multiplied by aT, so aT less than 1 means faster dynamics at the higher temperature.
What is the difference between WLF and Arrhenius behaviour?+
Arrhenius behaviour has a constant activation energy, so log aT is linear in 1/T. WLF behaviour has an apparent activation energy that is very large near Tg and drops quickly as T rises. At Tg = 373 K the WLF law corresponds to about 900 kJ/mol.
Why does the WLF equation diverge at Tg minus C2?+
The denominator C2 + T - Tref goes to zero when T = Tref - C2, which is 321.4 K for Tg = 373 K. This is the Vogel-like divergence of the equation and it signals that the formula cannot be applied that low.
How do I use WLF with time-temperature superposition?+
Measure modulus or viscosity curves at several temperatures, shift each along the log time axis by log aT to form a master curve at Tref, and fit C1 and C2 to the shift factors. The calculator then converts any temperature to its shift factor.
What is the reference viscosity at Tg?+
A viscosity of about 10^12 Pa s at the glass transition is a widely used convention for glass formers. For a polymer it depends on the sample and the definition of Tg, so the default of 1e12 Pa s here is illustrative.
Can I use WLF for relaxation time as well as viscosity?+
Yes. The same shift factor multiplies the relaxation time, tau(T) = tau_ref x aT, as well as the viscosity. The calculator reports both for the temperature you enter.

📚 Sources and Notes

The equation and its use with time-temperature superposition follow the Wikipedia article on the WLF equation and the IUPAC Gold Book definition, which describes the constants as valid from Tg to about Tg + 50 K. The universal constants 17.44 and 51.6 K are the commonly quoted textbook values. The reference viscosity, relaxation time, the constants in Example 4 and the Arrhenius activation energy are illustrative, so use data measured for your own polymer.

See also the polymer physics calculators.

What is the WLF equation?

The Williams-Landel-Ferry equation is an empirical formula for the shift factor in time-temperature superposition: log10 aT = -C1 (T - Tref) / (C2 + T - Tref). It describes how the time scale, and so viscosity and relaxation time, of a polymer changes with temperature above its glass transition.

What are the universal WLF constants?

When the reference temperature is Tg, the commonly quoted universal constants are C1 = 17.44 and C2 = 51.6 K. Constants for a particular polymer, or for a different reference temperature, differ and should be taken from fitted data.

How do you calculate viscosity from the WLF equation?

Find aT = 10^(log10 aT), then eta(T) = eta_ref x aT. At T = Tg + 20 K with universal constants, log10 aT = -17.44 x 20 / 71.6 = -4.872, aT = 1.344e-5, so a reference viscosity of 1e12 Pa s becomes 1.344e7 Pa s.

What temperature range is the WLF equation valid for?

It is intended for temperatures from Tg to roughly Tg + 100 K. The IUPAC Gold Book describes the constants as valid over a limited range of about Tg to Tg + 50 K. Below Tg it fails, and far above Tg the Arrhenius form usually fits better.

What does the shift factor aT mean?

aT is the factor by which time scales shift when temperature changes from Tref to T. Relaxation times and viscosities at T equal their values at Tref multiplied by aT, so aT less than 1 means faster dynamics at the higher temperature.

What is the difference between WLF and Arrhenius behaviour?

Arrhenius behaviour has a constant activation energy, so log aT is linear in 1/T. WLF behaviour has an apparent activation energy that is very large near Tg and drops quickly as T rises. At Tg = 373 K the WLF law corresponds to about 900 kJ/mol.

Why does the WLF equation diverge at Tg minus C2?

The denominator C2 + T - Tref goes to zero when T = Tref - C2, which is 321.4 K for Tg = 373 K. This is the Vogel-like divergence of the equation and it signals that the formula cannot be applied that low.

How do I use WLF with time-temperature superposition?

Measure modulus or viscosity curves at several temperatures, shift each along the log time axis by log aT to form a master curve at Tref, and fit C1 and C2 to the shift factors. The calculator then converts any temperature to its shift factor.

What is the reference viscosity at Tg?

A viscosity of about 10^12 Pa s at the glass transition is a widely used convention for glass formers. For a polymer it depends on the sample and the definition of Tg, so the default of 1e12 Pa s here is illustrative.

Can I use WLF for relaxation time as well as viscosity?

Yes. The same shift factor multiplies the relaxation time, tau(T) = tau_ref x aT, as well as the viscosity. The calculator reports both for the temperature you enter.