Reptation Time and Tube Length Calculator

Estimate the tube diameter and length, the number of entanglements and the reptation time of a linear polymer, and compare viscosity scaling.

🪢 Reptation Time and Tube Length Calculator
Polymer preset (illustrative)
Entanglement molar mass (Me)
g/mol
Molar mass (M)
g/mol
Temperature (T)
K
Segment molar mass (M0)
g/mol
Segment length (b)
nm
Segment friction (ζ, illustrative)
pN s/m
Reference viscosity (η1)
Pa s
Reference molar mass (M1)
g/mol
Target molar mass (M)
g/mol
Measured exponent (α)
Reptation time (τrep)
—
Entanglements (Z = M/Me)
—
Tube diameter (a)
—
Tube length (L)
—
Rouse time (τR)
—
Reptation D
—
Segments (N)
—
Segments per Me (Ne)
—

Viscosity, measured exponent
—
Viscosity, exponent 3
—
Measured / theory
—
Viscosity factor (measured)
—
Per doubling (3 / measured)
—
Crossover estimate Mc = 2 Me
—

🪢 What are Reptation Time and Tube Length?

In a melt or a concentrated solution of long linear polymers, chains cannot pass through each other. Each chain is trapped by its neighbours in a narrow, tortuous channel, and over long times it can only slither along its own length like a snake. This motion is called reptation. The tube model of de Gennes, Doi and Edwards turns this picture into numbers. The channel is a tube of diameter a, the chain follows the tube along a contour called the primitive path of length L, and the chain relaxes completely only when it has crawled out of its original tube. The time that takes is the reptation time, also called the disengagement time, and it controls the longest relaxation in the melt and with it the zero-shear viscosity.

The model needs only a few quantities. The entanglement molar mass Me is the mass of chain between constraints, so a chain of molar mass M carries Z = M/Me entanglements. The tube diameter follows from the entanglement length as a = b√Ne, where b is the segment length and Ne = Me/M0 is the number of segments per entanglement. The tube length is L = N b2/a = Z a, which is much shorter than the stretched contour length. The Rouse time τR = N2 ζ b2 / (3 π2 k T) measures how long a free-draining chain takes to relax along its length, and the reptation time is τrep = 3 Z τR. Since τR grows as M2 and Z as M, the reptation time grows as M3.

The prediction is close to experiment but not identical. Measured melt viscosities scale as M3.4, and the second mode of this calculator lets you compare the two exponents directly. The result is that the 0.4 difference in exponent becomes a factor of about 6 over two decades of molar mass. The model also assumes a linear, monodisperse chain well above the entanglement threshold, so the page reports when Z is below 1 and when your viscosity range crosses the rough crossover mass of about 2 Me. Use it to plan rheology experiments, to estimate how long a sample must relax before processing, or to teach the connection between molecular parameters and flow. For the diffusion side of the same physics see the polymer diffusion coefficient calculator, and for temperature shifts of the friction see the WLF viscosity calculator.

📐 Formula

τrep  =  3 Z τR,    τR  =  N2 ζ b2 ÷ (3 π2 k T)
Z = M / Me, the number of entanglements per chain
N = M / M0, the number of segments; Ne = Me / M0
b = segment length (m); ζ = friction of one segment (kg/s)
a = b √Ne, the tube diameter; L = N b2 / a = Z a, the tube length
Drep = Dc / (3 Z) with Dc = k T / (N ζ), the centre-of-mass diffusion coefficient
Example: M = 100,000 g/mol, Me = 1000, M0 = 150, b = 1.4 nm, ζ = 20 pN s/m, T = 413 K gives Z = 100, τR = 1.032 × 10-4 s and τrep = 3.096 × 10-2 s
η  =  η1 (M ÷ M1)α,    α = 3 (tube model), α ≈ 3.4 (measured)
η1 = viscosity at reference molar mass M1 (Pa s)
α = viscosity exponent for entangled linear melts
Example: η1 = 1000 Pa s at 50,000 g/mol gives 8000 Pa s (exponent 3) or 10,556 Pa s (exponent 3.4) at 100,000 g/mol

📖 How to Use This Calculator

Two modes

1
Pick a preset or enter Me - The illustrative presets fill the entanglement molar mass, the segment molar mass and the segment length together. Typing a different Me switches the preset to Custom.
2
Tube and times - Enter the molar mass, the temperature and the segment friction. The calculator returns Z, the tube diameter and length, the Rouse and reptation times and the diffusion coefficient.
3
Viscosity scaling - Enter a viscosity at a reference molar mass, a target molar mass and the measured exponent to compare the M3 prediction with the M3.4 behaviour.
4
Read the chart - The log-log chart shows time or viscosity against molar mass, with a dashed guide at your chosen M. Slopes of 3 and 3.4 are easy to compare by eye.

💡 Example Calculations

Example 1 - A polyethylene-like melt of 100,000 g/mol

M = 100,000, Me = 1000, M0 = 150, b = 1.4 nm, ζ = 20 pN s/m, T = 413 K

1
N = 100,000 / 150 = 666.7, Ne = 1000 / 150 = 6.67 and Z = 100. The tube diameter is a = 1.4 × √6.67 = 3.615 nm.
2
Tube length L = N b2/a = 361.5 nm, and the Rouse time is τR = 1.032 × 10-4 s.
3
τrep = 3 × 100 × 1.032 × 10-4 = 3.096 × 10-2 s and Drep = 1.426 × 10-15 m2/s.
τrep = 3.096e-2 s, tube length = 361.5 nm, Z = 100.00
Try this example →

Example 2 - Four times the molar mass

M = 400,000 g/mol, other inputs as in Example 1

1
Z rises to 400 and N to 2666.7, so the tube length grows to 1445.9 nm while the tube diameter stays 3.615 nm.
2
τR grows by 42 = 16 to 1.651 × 10-3 s.
3
τrep = 3 × 400 × 1.651 × 10-3 = 1.981 s, which is 64 times the value at 100,000 g/mol, as expected for M3.
τrep = 1.981 s, tube length = 1,445.9 nm
Try this example →

Example 3 - A polystyrene-like melt

M = 100,000, Me = 13,000, M0 = 720, b = 1.8 nm, ζ = 20 pN s/m, T = 450 K (all illustrative)

1
N = 138.9, Ne = 18.06 and Z = 7.69, so the chain is only weakly entangled. The tube diameter is a = 1.8 × √18.06 = 7.649 nm.
2
Tube length L = 58.83 nm and τR = 6.795 × 10-6 s.
3
τrep = 3 × 7.692 × 6.795 × 10-6 = 1.568 × 10-4 s and Drep = 9.692 × 10-14 m2/s.
τrep = 1.568e-4 s, tube diameter = 7.649 nm
Try this example →

Example 4 - Viscosity when the molar mass doubles

η1 = 1000 Pa s at 50,000 g/mol, target 100,000 g/mol, α = 3.4

1
The molar mass ratio is 2. With the tube-model exponent the viscosity is 1000 × 23 = 8000 Pa s.
2
With the measured exponent it is 1000 × 23.4 = 10,556 Pa s, a factor 10.556 above the reference.
3
The ratio of measured to tube-model viscosity is 10,556 / 8000 = 1.320, and the crossover estimate Mc = 2 Me is 2000 g/mol, well below both masses.
η = 10,556.1 Pa s (measured exponent), 8000.0 Pa s (exponent 3)
Try this example →

❓ Frequently Asked Questions

What is reptation in polymer physics?+
Reptation is the snake-like motion of a long chain along the contour of a tube formed by the surrounding entangled chains. Lateral motion is blocked by the neighbours, so the chain can only diffuse along its own length, as proposed by de Gennes and developed by Doi and Edwards.
How is the reptation time calculated?+
The disengagement time is tau_rep = 3 Z tau_R, where Z = M/Me is the number of entanglements and tau_R = N^2 zeta b^2 / (3 pi^2 k T) is the Rouse time of the chain. Because tau_R grows as N^2 and Z as N, tau_rep grows as M^3.
What is the tube diameter and how is it found?+
The tube diameter a is the typical distance a chain wanders sideways before feeling the constraint of neighbours. Here a = b sqrt(Ne), with b the segment length and Ne = Me/M0 the number of segments per entanglement length. It is a few nanometres for flexible polymers.
How do you compute the tube length?+
The tube length is the primitive path length, L = N b^2 / a, which equals Z a. For 666.7 segments of 1.4 nm with a = 3.615 nm the tube is 361.5 nm long, much shorter than the fully stretched contour length N b = 933 nm.
What is the entanglement molar mass Me?+
Me is the molar mass of a chain section between entanglements, often obtained from the rubbery plateau modulus as Me = rho R T / G_N0. The number of entanglements per chain is Z = M/Me. Typical values run from about one thousand g/mol for polyethylene to over ten thousand for polystyrene.
Why is the viscosity exponent 3.4 rather than 3?+
The tube model predicts viscosity proportional to M^3, since eta is the plateau modulus times the disengagement time and the modulus does not depend on M. Measurements on linear melts give about 3.4. Fluctuations of the tube length and constraint release are the usual explanations.
What is the reptation diffusion coefficient?+
The centre of mass diffuses as D = D_c / (3 Z), where D_c = k T / (N zeta) is the curvilinear diffusion coefficient along the tube. This gives D proportional to M^-2. For the default 100,000 g/mol chain, D is 1.426e-15 m^2/s.
How does the reptation time depend on molar mass?+
Doubling M multiplies the tube-model time by 2^3 = 8, and by about 2^3.4 = 10.6 for measured viscosities. Going from 100,000 to 400,000 g/mol with the default inputs raises tau_rep from 0.031 s to 1.98 s, a factor of 64.
Does the tube model apply to short chains?+
No. Below about Z = 1 to 3 the chain is not confined and follows Rouse dynamics, with viscosity roughly proportional to M. The calculator flags chains with Z below 1 and the viscosity mode warns when part of the range lies under the crossover estimate Mc of about 2 Me.
Can I use this for branched polymers or blends?+
Not directly. Reptation describes linear monodisperse chains. Branches slow relaxation exponentially in arm length and polydispersity adds constraint release, so branched or blended melts need extended tube models. Use the results as a baseline for the linear case.

📚 Sources and Notes

The tube picture, the M3 viscosity prediction and its mismatch with the measured M3.4 dependence are discussed in these tube model lecture notes and in the Physical Review Letters paper Towards an Explanation of the 3.4-Power Dependence of the Viscosity on Molecular Weight. A single-molecule study states the longest relaxation time as τD = (18 RG2/a2) τR (arXiv 0706.3414), which equals 3 Z τR when RG2 = N b2/6 and Z = N b2/a2. The diffusion form D = Dc/(3Z) is the standard Doi-Edwards expression from the textbook and was not checked against an online source. The Me presets, segment masses, segment lengths and the friction of 20 pN s/m are rounded illustrative values, not measured constants, and the exponent 3.4 is a typical experimental value. Different texts use different numerical prefactors for the reptation time, so only the scaling is robust.

See also the polymer physics calculators.

What is reptation in polymer physics?

Reptation is the snake-like motion of a long chain along the contour of a tube formed by the surrounding entangled chains. Lateral motion is blocked by the neighbours, so the chain can only diffuse along its own length, as proposed by de Gennes and developed by Doi and Edwards.

How is the reptation time calculated?

The disengagement time is tau_rep = 3 Z tau_R, where Z = M/Me is the number of entanglements and tau_R = N^2 zeta b^2 / (3 pi^2 k T) is the Rouse time of the chain. Because tau_R grows as N^2 and Z as N, tau_rep grows as M^3.

What is the tube diameter and how is it found?

The tube diameter a is the typical distance a chain wanders sideways before feeling the constraint of neighbours. Here a = b sqrt(Ne), with b the segment length and Ne = Me/M0 the number of segments per entanglement length. It is a few nanometres for flexible polymers.

How do you compute the tube length?

The tube length is the primitive path length, L = N b^2 / a, which equals Z a. For 666.7 segments of 1.4 nm with a = 3.615 nm the tube is 361.5 nm long, much shorter than the fully stretched contour length N b = 933 nm.

What is the entanglement molar mass Me?

Me is the molar mass of a chain section between entanglements, often obtained from the rubbery plateau modulus as Me = rho R T / G_N0. The number of entanglements per chain is Z = M/Me. Typical values run from about one thousand g/mol for polyethylene to over ten thousand for polystyrene.

Why is the viscosity exponent 3.4 rather than 3?

The tube model predicts viscosity proportional to M^3, since eta is the plateau modulus times the disengagement time and the modulus does not depend on M. Measurements on linear melts give about 3.4. Fluctuations of the tube length and constraint release are the usual explanations.

What is the reptation diffusion coefficient?

The centre of mass diffuses as D = D_c / (3 Z), where D_c = k T / (N zeta) is the curvilinear diffusion coefficient along the tube. This gives D proportional to M^-2. For the default 100,000 g/mol chain, D is 1.426e-15 m^2/s.

How does the reptation time depend on molar mass?

Doubling M multiplies the tube-model time by 2^3 = 8, and by about 2^3.4 = 10.6 for measured viscosities. Going from 100,000 to 400,000 g/mol with the default inputs raises tau_rep from 0.031 s to 1.98 s, a factor of 64.

Does the tube model apply to short chains?

No. Below about Z = 1 to 3 the chain is not confined and follows Rouse dynamics, with viscosity roughly proportional to M. The calculator flags chains with Z below 1 and the viscosity mode warns when part of the range lies under the crossover estimate Mc of about 2 Me.

Can I use this for branched polymers or blends?

Not directly. Reptation describes linear monodisperse chains. Branches slow relaxation exponentially in arm length and polydispersity adds constraint release, so branched or blended melts need extended tube models. Use the results as a baseline for the linear case.