Melting Temperature Depression Calculator (Flory)
Predict how a diluent, a comonomer or a thin lamella lowers the melting point of a semicrystalline polymer below its equilibrium value.
🌡️ What is Melting Temperature Depression?
A pure, infinitely large and perfect crystal of a polymer melts at its equilibrium melting temperature Tm0. Real samples melt lower. Anything that lowers the chemical potential of the molten state relative to the crystal, or raises the free energy of the crystal, depresses the melting point. Three causes dominate in polymer science. A low molar mass diluent mixed into the melt stabilises the liquid by the entropy and enthalpy of mixing. A comonomer that cannot enter the crystal lattice dilutes the crystallizable sequences in the same way. And a thin lamella with folded surfaces carries a surface free energy penalty that makes small crystals melt early. This calculator handles all three.
For a polymer with a diluent, Flory showed that 1/Tm - 1/Tm0 = (R/ΔHu)(Vu/V1)(φ1 - χ φ12). Here ΔHu is the heat of fusion per repeat unit, Vu and V1 are the molar volumes of the repeat unit and the diluent, φ1 is the diluent volume fraction and χ is the Flory-Huggins interaction parameter. A smaller χ means a better solvent and a larger depression, and fitting this equation to melting data is a classic way to measure χ. For a random copolymer in which the second monomer is fully excluded from the crystal, Flory's 1955 result is 1/Tm - 1/Tm0 = -(R/ΔHu) ln XA, with XA the mole fraction of crystallizable units. Finally, the Gibbs-Thomson relation Tm = Tm0(1 - 2σe/(ΔHv l)) links the melting point to the lamellar thickness l, the fold surface free energy σe and the heat of fusion per crystal volume.
These models make different assumptions, so choose the one that matches your sample. The diluent and copolymer forms give equilibrium values that apply to crystals of effectively infinite thickness, while the Gibbs-Thomson form describes the size effect on its own. In practice they combine, and a real peak sits below all three predictions. Comonomer inclusion in the crystal, polydispersity, chain ends and thickening during heating all shift the result, so the page reports the depression relative to Tm0 rather than claiming an absolute prediction. The presets are rounded illustrative numbers for polyethylene, polypropylene and PET and you should replace them with values cited for your material. To go from enthalpy to crystalline content see the DSC crystallinity calculator, and for χ itself see the Flory-Huggins interaction parameter calculator.
📐 Formula
📖 How to Use This Calculator
Three modes
💡 Example Calculations
Example 1 - Polyethylene with 30 percent diluent
Tm0 = 414.6 K, ΔHu = 4.11 kJ/mol, Vu = 16.5, V1 = 123 cm³/mol, φ1 = 0.3, χ = 0.3
Example 2 - The same system in an ideal diluent
Same inputs, χ = 0
Example 3 - Polyethylene with 5 mol percent comonomer
Tm0 = 414.6 K, ΔHu = 4.11 kJ/mol, XA = 0.95
Example 4 - A 10 nm polyethylene lamella
Tm0 = 414.6 K, σe = 90 mJ/m², ΔHf = 293 J/g, ρc = 1.00 g/cm³, l = 10 nm
❓ Frequently Asked Questions
📚 Sources and Notes
The diluent equation and its interpretation, including the role of χ and the high molar mass limit, are described in the study of polypropylene melting point depression by alkanes. The copolymer form and its assumption that the comonomer is excluded from the crystal are covered in the NIST analysis Crystallization of random copolymers, and the Gibbs-Thomson relation between melting point and lamellar thickness in this paper on the Gibbs-Thomson equation for polymers. The molar volume ratio of 16.5/123, the heat of fusion per repeat unit, the equilibrium melting points and the surface free energies of 90 to 100 mJ/m² in the presets are rounded illustrative values and not confirmed against a cited table, and the fold surface energy for polypropylene and PET in particular is a placeholder. Treat every result as a model estimate.
See also the polymer physics calculators.
🔗 Related Calculators
What is melting point depression in polymers?
It is the lowering of the melting temperature of a crystalline polymer by something that is rejected from the crystal, such as a diluent, a comonomer unit or defects, or by the finite thickness of the crystal. The depression is predicted by the Flory theory and by the Gibbs-Thomson equation.
What is the Flory equation for a polymer with a diluent?
1/Tm - 1/Tm0 = (R/dHu)(Vu/V1)(phi1 - chi phi1^2), where dHu is the heat of fusion per repeat unit, Vu and V1 are the molar volumes of the repeat unit and diluent, phi1 the diluent volume fraction and chi the Flory-Huggins parameter.
How does the interaction parameter chi change the result?
The term phi1 - chi phi1^2 shrinks as chi grows, so a poor solvent depresses the melting point less than a good one. With the default inputs the melting point is 401.06 K at chi = 0, 402.24 K at chi = 0.3 and 403.04 K at chi = 0.5.
What is the Flory copolymer melting equation?
For a random copolymer in which comonomer B is excluded from the crystals of A, 1/Tm - 1/Tm0 = -(R/dHu) ln X_A, where X_A is the mole fraction of crystallizable units. Five mole percent of excluded comonomer lowers polyethylene from 414.6 K to 397.5 K.
What is the Gibbs-Thomson equation for polymer crystals?
Tm = Tm0 (1 - 2 sigma_e / (dHv l)), with sigma_e the fold surface free energy, dHv the heat of fusion per unit volume of crystal and l the lamellar thickness. A plot of Tm against 1/l is linear and its intercept at 1/l = 0 is Tm0.
What is the equilibrium melting temperature Tm0?
It is the melting temperature of an infinitely large, perfect crystal of the polymer, which cannot be measured directly. It is obtained by extrapolation, for example from Hoffman-Weeks or Gibbs-Thomson plots, and values for one polymer differ by several kelvin between publications.
Why is measured Tm lower than Tm0?
Real polymer crystals are thin lamellae with folded surfaces of high free energy, and often contain defects. With sigma_e = 90 mJ/m2 a 10 nm polyethylene lamella melts about 25 K below Tm0, which is the typical size of the gap seen in DSC.
Do the Flory equations work for short chains?
The diluent equation is written for a high molar mass polymer. For short chains and oligomers end groups also lower the melting point, so extra terms appear. Use the results as an upper estimate when the degree of polymerization is small.
How do I find the number of repeat units per volume?
Divide the repeat unit molar mass by the amorphous density to get Vu in cm3/mol, for example about 16.5 cm3/mol for a CH2 unit in the melt. The default value is illustrative, as is the diluent volume of 123 cm3/mol.
What are the units used by this calculator?
Temperatures are in kelvin with a degree Celsius conversion, heat of fusion per repeat unit in kJ/mol or per gram in J/g, molar volumes in cm3/mol, surface free energy in mJ/m2, density in g/cm3 and thickness in nm. R is 8.314 J/(mol K).