Mark-Houwink Viscosity Calculator
Use the Mark-Houwink equation to link intrinsic viscosity and molar mass, or extract [eta] from dilute-solution viscosity data with a Huggins plot.
🧪 What is the Mark-Houwink Equation?
The Mark-Houwink equation, also called the Mark-Houwink-Sakurada equation, is the empirical power law [η] = K Ma that connects the intrinsic viscosity of a dilute polymer solution to the molar mass of the polymer. The intrinsic viscosity [η] measures how much a single, isolated polymer coil increases the viscosity of a solvent. Long chains occupy more hydrodynamic volume, so [η] rises with molar mass, and the constants K and a describe exactly how steeply. Because a viscometer is far cheaper and quicker to run than a light scattering instrument, the equation is one of the most widely used routes to a polymer molar mass.
The exponent a carries structural information. A flexible chain in a theta solvent behaves as an unperturbed coil and gives a = 0.5. In a good solvent the coil swells and a climbs towards 0.7 or 0.8. Stiffer or more extended chains, such as semiflexible polymers or polyelectrolytes, give a above 1, and the limit for a rigid rod is close to 2. For a = 1 the equation becomes the Staudinger form. The prefactor K is not universal: it depends on the polymer, solvent and temperature, which is why every published pair of constants quotes all three. This calculator treats the preset values as illustrative and invites you to replace them with constants for your own system.
The second mode handles the measurement side. In practice [η] is not read from one run but extrapolated from several dilute concentrations. The Huggins equation, ηsp/c = [η] + kH [η]2 c, makes the reduced viscosity linear in concentration, so a straight-line fit returns [η] as the intercept and the Huggins coefficient kH from the slope. The Kraemer relation ln(ηrel)/c = [η] − kK [η]2 c converges on the same intercept, so agreement between the two is a quick quality check.
A subtle point is which molar mass the equation returns. A real sample has a distribution of chain lengths, and the viscosity responds to a particular weighting of them, giving the viscosity-average molar mass Mv. It lies between the number-average Mn and the weight-average Mw, and sits close to Mw. See the number-average and weight-average molecular weight calculator for the averages, and the radius of gyration calculator for the matching size scaling.
📐 Formula
📖 How to Use This Calculator
Two modes
💡 Example Calculations
Example 1 - Intrinsic viscosity of a 100,000 g/mol polymer
K = 0.014 mL/g (illustrative), a = 0.70, M = 100,000 g/mol
Example 2 - Molar mass from a measured viscosity
[η] = 0.9 dL/g, K = 0.014 mL/g (illustrative), a = 0.70
Example 3 - Calibrating K from a standard
A standard with M = 250,000 g/mol has [η] = 1.2 dL/g, and a = 0.70 is assumed
Example 4 - Huggins extrapolation from four concentrations
c = 0.2, 0.4, 0.6, 0.8 g/dL with ηsp = 0.169, 0.3558, 0.5606, 0.7834
❓ Frequently Asked Questions
📚 Sources and Notes
The Huggins relation and typical kH range follow the Wikipedia article on the Huggins equation and the reduced viscosity article. The form [η] = K Ma and the role of K and a are described in the IUPAC Gold Book entry and the Polymer Science Learning Center page on dilute solution viscosity. The preset values of K and a are illustrative round numbers, not certified reference data.
See also the polymer physics calculators, the degree of polymerization calculator and the Flory exponent calculator.
🔗 Related Calculators
What is the Mark-Houwink equation?
The Mark-Houwink equation, also called the Mark-Houwink-Sakurada equation, is the power law [eta] = K M^a that links the intrinsic viscosity of a dilute polymer solution to its molar mass. K and a depend on the polymer, solvent and temperature.
How do you calculate intrinsic viscosity from molar mass?
Multiply K by the molar mass raised to the power a. With K = 0.014 mL/g, a = 0.70 and M = 100,000 g/mol, [eta] = 0.014 x 100,000^0.70 = 44.27 mL/g, which is 0.4427 dL/g.
What values can the exponent a take?
For flexible random coils a runs from 0.5 in a theta solvent up to about 0.8 in a good solvent. Stiffer chains give higher values, and the limit for a rigid rod is close to 2. A value of 1 is the Staudinger form.
What is viscosity-average molar mass Mv?
Mv is the molar mass obtained when a polydisperse sample is put into the Mark-Houwink equation. It equals (sum of w_i M_i^a)^(1/a) over weight fractions w_i. It lies between Mn and Mw, equals Mw when a = 1, and is usually quite close to Mw.
How do you find intrinsic viscosity from experimental data?
Measure the specific viscosity at several dilute concentrations and plot eta_sp / c against c (Huggins). The intercept at c = 0 is [eta], and the slope equals k_H [eta]^2. A Kraemer plot of ln(eta_rel) / c gives the same intercept as a check.
What is the Huggins coefficient k_H?
k_H is the dimensionless slope constant of the Huggins plot, k_H = slope / [eta]^2. Typical values run from about 0.3 in good solvents to about 0.5 in poorer solvents. Values far outside that range often signal aggregation or scatter.
What units does intrinsic viscosity have?
Intrinsic viscosity is a volume per mass, usually dL/g, mL/g or cm3/g. Note that 1 dL/g equals 100 mL/g and 1 mL/g equals 1 cm3/g. K carries matching units of volume per mass per (g/mol)^a.
How do you find K and a for a polymer?
Measure [eta] for several narrow-distribution standards of known molar mass and plot log [eta] against log M. The slope is a and the intercept is log K. This calculator can solve K when you know a, M and [eta] for one standard.
Why is intrinsic viscosity used to find molar mass?
Capillary viscometry is cheap and fast compared with light scattering or osmometry. Once K and a are known for a polymer-solvent pair, one dilute-solution viscosity series gives Mv. It is a relative method that needs calibration constants.
Are the K and a presets exact?
No. The presets are illustrative round values for a polystyrene in tetrahydrofuran style system, a theta-type case and a poly(methyl methacrylate) style system. Published constants vary with temperature, solvent grade and molar mass range, so replace them with values for your system.