Watts to Lux Calculator

Turn lamp watts into lumens with the luminous efficacy, then into lux for a room or at a distance, with the geometry made explicit.

💡 Watts to Lux Calculator

Watts cannot be converted to lux on their own. You need the luminous efficacy (lm/W) to get lumens and the geometry (area or distance) to get lux.

Lamp power (electrical input)
W
1500
Lamp type (illustrative)
Luminous efficacy
lm/W
Room floor area
m²
1100
Utilisation factor (illustrative 0.5)
Task (illustrative)
Target illuminance
lx
Beam angle (full cone)
°
Angle of incidence
°
Distance (d)
m
0.510
Average illuminance
—
Luminous flux
—
Foot-candles
—
Target
—
Share of target
—
Watts needed for target
—
Power density
—

Illuminance at the surface
—
Luminous intensity
—
Luminous flux
—
Solid angle
—
Foot-candles
—
Lux if facing the lamp
—

💡 What is a Watts to Lux Conversion?

A watts to lux conversion estimates how brightly a lamp lights a surface starting from its electrical power. It is a two step process, and it cannot be done in one step. Watts measure the electrical power a lamp draws. Lumens measure the light it produces, weighted by the sensitivity of the human eye. Lux measures how much of that light lands on each square metre of a surface. Going from watts to lumens needs the luminous efficacy of the lamp in lumens per watt. Going from lumens to lux needs the geometry: the area over which the light is spread, or the distance and angle if the lamp is small.

That is why a question such as "how many lux is a 60 watt bulb?" has no single answer. A 60 W incandescent lamp and a 60 W LED fixture give very different lumens, and the same lumens give very different lux in a tiny cupboard and in a large hall. This calculator makes each assumption a visible input. In Room lighting mode it multiplies watts by efficacy to get lumens, applies a utilisation factor for light that reaches the work plane, and divides by the floor area. It also works backwards to the watts needed for a target lux. In Point source mode it turns the lumens into candela using the beam angle, then applies the inverse square law with an angle of incidence.

People use it for home lighting plans, for comparing old and new lamps, for photography and video lighting, for greenhouse and workshop planning, and for physics homework. The lamp type presets (incandescent 14, halogen 20, CFL 60 and LED 100 lm/W) and the task presets (hallway 100 lx up to 1000 lx for detailed work) are illustrative round numbers, not product data and not a standard. Replace them with the figures on your lamp and the requirements that apply to your project.

Two cautions apply. Efficacy must be per electrical input watt, the same watts you enter, otherwise lumens are overstated. The room estimate is an average on the work plane and ignores uneven layouts, shadows and daylight, and the point source estimate ignores reflections. If you already know the lumens, use the lumen calculator; for energy use over time see the watt-hour calculator.

📐 Formula

E  =  ( P × η × U ) / A    or    E  =  I cos α / d²
P = lamp electrical input power (W)
η = luminous efficacy (lm/W), so the luminous flux is Φ = P η in lumens
U = utilisation factor (0 to 1), the share of the lumens that reaches the work plane
A = floor area (m²); E is the average illuminance in lux (lm/m²)
Point source: Ω = 2π ( 1 − cos( θ / 2 ) ) for a full beam angle θ, and I = Φ / Ω in candela
I = luminous intensity (cd), d = distance (m), α = angle between the light ray and the surface normal
Watts needed: P = E A / ( U η ); and 1 foot-candle = 10.7639 lux
Example: 10 W LED at 100 lm/W = 1000 lm; in 12 m² with U = 0.5 that is 41.7 lx

📖 How to Use This Calculator

Steps

1
Enter the lamp watts and efficacy. Type the electrical power in watts and pick a lamp type preset, or enter the luminous efficacy in lm/W from the datasheet.
2
Add the geometry. For Room lighting, enter the floor area, a utilisation factor and a target lux (or choose a task). For Point source, enter the beam angle, the distance and the angle of incidence.
3
Read the lux and the chart. The main box gives the illuminance, the other boxes give the lumens, foot-candles and the watts needed for the target, and the chart shows how the lux changes with area or distance.

💡 Example Calculations

Example 1 — 10 W LED in a 12 m² Living Room

10 W, 100 lm/W (illustrative LED), area 12 m², utilisation factor 0.5, target 150 lx

1
Lumens = 10 W × 100 lm/W = 1000 lm
2
E = 1000 × 0.5 / 12 = 41.667 lx, which is 3.871 foot-candles and 27.8 percent of the 150 lx target
3
Watts needed = 150 × 12 / ( 0.5 × 100 ) = 36 W at the same efficacy
Illuminance = 41.667 lx, watts needed for 150 lx = 36 W
Try this example →

Example 2 — 60 W Incandescent Lamp in a 10 m² Room

60 W, 14 lm/W (illustrative incandescent), area 10 m², utilisation factor 0.5, target 150 lx

1
Lumens = 60 × 14 = 840 lm
2
E = 840 × 0.5 / 10 = 42 lx
3
The same 840 lm from an LED at 100 lm/W needs only 8.4 W, so the 60 W lamp uses about 7 times the power for the same light
Illuminance = 42 lx from 840 lm
Try this example →

Example 3 — Kitchen Panel and a 300 lx Target

40 W, 100 lm/W, area 15 m², utilisation factor 0.6, target 300 lx

1
Lumens = 40 × 100 = 4000 lm
2
E = 4000 × 0.6 / 15 = 160 lx, which is 53.3 percent of the 300 lx target
3
Watts needed = 300 × 15 / ( 0.6 × 100 ) = 75 W
Illuminance = 160 lx, watts needed for 300 lx = 75 W
Try this example →

Example 4 — 10 W LED Spot at 2 Metres

10 W, 100 lm/W, beam angle 120 degrees, distance 2 m, surface facing the lamp

1
Lumens = 1000 lm, and solid angle Ω = 2π ( 1 − cos 60° ) = 3.1416 sr
2
Intensity I = 1000 / 3.1416 = 318.31 cd
3
E = 318.31 / 2² = 79.577 lx, which is 7.393 foot-candles
Illuminance = 79.577 lx at 2 m
Try this example →

Example 5 — The Same Spot on a Tilted Surface

10 W, 100 lm/W, beam 120 degrees, distance 2 m, angle of incidence 30 degrees

1
Intensity I = 1000 lm / 3.1416 sr = 318.31 cd, as before
2
E = 318.31 × cos 30° / 2² = 318.31 × 0.86603 / 4 = 68.916 lx
3
Tilting the surface by 30 degrees cuts the lux by 13.4 percent compared with the 79.577 lx on a surface that faces the lamp
Illuminance = 68.916 lx (79.577 lx facing the lamp)
Try this example →

Example 6 — Bare 100 W Incandescent Bulb Shining in All Directions

100 W, 14 lm/W (illustrative), beam angle 360 degrees, distance 3 m, facing the lamp

1
Lumens = 100 × 14 = 1400 lm, and Ω = 2π ( 1 − cos 180° ) = 12.566 sr
2
I = 1400 / 12.566 = 111.41 cd
3
E = 111.41 / 3² = 12.379 lx
Illuminance = 12.379 lx at 3 m
Try this example →

❓ Frequently Asked Questions

How do you convert watts to lux?+
You cannot convert directly. First convert watts to lumens with the luminous efficacy (lumens = watts x lm/W), then convert lumens to lux with the geometry: lux = lumens x utilisation / area for a room, or lux = candela x cos(angle) / distance squared for a point source.
How many lumens is a watt?+
It depends on the lamp. The luminous efficacy is the lumens per watt, and it is different for every light source. Illustrative values are about 14 lm/W for an incandescent lamp, 20 for a halogen, 60 for a CFL and 100 for an LED, but real products vary.
What is the maximum luminous efficacy?+
The theoretical maximum for monochromatic green light at 555 nm is 683 lm/W of radiant power. Real white light sources are well below that because they spread power over many wavelengths and lose energy as heat.
How many lux do I need in a room?+
It depends on the task. Illustrative round numbers are about 100 lux for a hallway, 150 for a living room, 300 for a kitchen and 500 for an office desk, but you should follow the recommendations that apply to your country and use.
How do I calculate the lux in a room from the bulb watts?+
Multiply watts by efficacy to get lumens, multiply by a utilisation factor for the light that reaches the work plane, and divide by the floor area in square metres. A 10 W LED at 100 lm/W in a 12 m2 room with a factor of 0.5 gives 41.7 lux.
What is the difference between lumens and lux?+
Lumens measure the total light a source emits. Lux measures how much of that light falls on each square metre of a surface, so one lumen spread over one square metre is one lux. The same lamp gives more lux on a small area than on a large one.
How does distance change the lux?+
For a small source the illuminance falls with the square of the distance. Doubling the distance cuts lux to a quarter. That is the inverse square law, E = I / d squared, and it holds when the lamp is small compared with the distance.
What is the angle of incidence?+
It is the angle between the light ray and the normal (the perpendicular) of the surface. At 0 degrees the light hits the surface straight on. At 60 degrees the lux falls to half because cos(60 degrees) is 0.5.
What is a foot-candle?+
A foot-candle is one lumen per square foot, equal to 10.764 lux. The calculator shows both so you can compare with older US specifications.
How is this different from the lumen calculator?+
The lumen calculator starts from lumens. This one starts from the electrical watts of the lamp and the luminous efficacy, so it answers questions such as how many lux a 10 W LED gives, and how many watts a room needs for a target lux.

How do you convert watts to lux?

You cannot convert directly. First convert watts to lumens with the luminous efficacy (lumens = watts x lm/W), then convert lumens to lux with the geometry: lux = lumens x utilisation / area for a room, or lux = candela x cos(angle) / distance squared for a point source.

How many lumens is a watt?

It depends on the lamp. The luminous efficacy is the lumens per watt, and it is different for every light source. Illustrative values are about 14 lm/W for an incandescent lamp, 20 for a halogen, 60 for a CFL and 100 for an LED, but real products vary.

What is the maximum luminous efficacy?

The theoretical maximum for monochromatic green light at 555 nm is 683 lm/W of radiant power. Real white light sources are well below that because they spread power over many wavelengths and lose energy as heat.

How many lux do I need in a room?

It depends on the task. Illustrative round numbers are about 100 lux for a hallway, 150 for a living room, 300 for a kitchen and 500 for an office desk, but you should follow the recommendations that apply to your country and use.

How do I calculate the lux in a room from the bulb watts?

Multiply watts by efficacy to get lumens, multiply by a utilisation factor for the light that reaches the work plane, and divide by the floor area in square metres. A 10 W LED at 100 lm/W in a 12 m2 room with a factor of 0.5 gives 41.7 lux.

What is the difference between lumens and lux?

Lumens measure the total light a source emits. Lux measures how much of that light falls on each square metre of a surface, so one lumen spread over one square metre is one lux. The same lamp gives more lux on a small area than on a large one.

How does distance change the lux?

For a small source the illuminance falls with the square of the distance. Doubling the distance cuts lux to a quarter. That is the inverse square law, E = I / d squared, and it holds when the lamp is small compared with the distance.

What is the angle of incidence?

It is the angle between the light ray and the normal (the perpendicular) of the surface. At 0 degrees the light hits the surface straight on. At 60 degrees the lux falls to half because cos(60 degrees) is 0.5.

What is a foot-candle?

A foot-candle is one lumen per square foot, equal to 10.764 lux. The calculator shows both so you can compare with older US specifications.

How is this different from the lumen calculator?

The lumen calculator starts from lumens. This one starts from the electrical watts of the lamp and the luminous efficacy, so it answers questions such as how many lux a 10 W LED gives, and how many watts a room needs for a target lux.