Watts to Amps Calculator

Find the current drawn by a load from its power in watts, for DC, single-phase AC with power factor, and balanced three-phase systems.

🔌 Watts to Amps Calculator
Power (P)
DC voltage (V)
V
AC voltage (V)
V
Power factor (PF, illustrative 0.9)
Line-to-line voltage (V)
V
Power factor (PF, illustrative 0.9)
Current
—
Milliamps
—
Power used
—
Voltage used
—

Current
—
Current at PF = 1
—
Apparent power
—
Reactive power
—
Power factor used
—
Real power
—

Line current
—
Delta winding current
—
Apparent power
—
Reactive power
—
Power factor used
—
Real power
—

Current only sets the minimum conductor size. For cable sizing use the wire gauge calculator and your local electrical code.

🔌 What is a Watts to Amps Conversion?

A watts to amps conversion finds the electric current that a load draws when you know its power. Watts measure power, the rate at which electrical energy is used. Amps measure current, the rate at which charge flows. The two are linked by the supply voltage, because electric power is voltage multiplied by current. That is why the question "how many amps is 1000 watts?" has no single answer: it is 83.3 A at 12 V, 8.33 A at 120 V and 4.35 A at 230 V. For alternating current the picture has two more factors: the power factor, which says how much of the apparent power is actually doing work, and the number of phases in the supply.

The conversion matters whenever you choose cables, fuses, breakers, plugs, generators, inverters or battery banks. A 3 kW inverter on a 12 V battery pulls about 250 A before conversion losses, which needs heavy cable and a large fuse. The same 3 kW on a 230 V circuit pulls 13 A. An electrician checking a motor circuit needs the line current for a three-phase supply, and a camper van owner sizing a solar system needs the DC current at 12 or 24 V. The comparison table in the calculator shows the same power at 12, 24, 120, 230 and 400 V so you can see the effect of the voltage choice immediately.

There are three formulas. For DC, the current is the power divided by the voltage. For single-phase AC, it is the power divided by the voltage and the power factor. For a balanced three-phase load, it is the power divided by the square root of 3, the line-to-line voltage and the power factor. A common error is to forget the power factor or the square root of 3, which makes the answer wrong by about 11 percent at a power factor of 0.9 and by a factor of 1.73 if the square root of 3 is dropped. Another is to use the phase voltage (230 V) in the three-phase formula instead of the line-to-line voltage (400 V).

The tool also reports the apparent power in volt-amperes and the reactive power in vars for AC loads, plus the winding current for a delta connection. It does not size the cable. Cable selection depends on insulation rating, length, installation method and local rules, so use the current here as an input to the wire gauge calculator. For the reverse direction, power from a motor rating in horsepower, see the hp to amps calculator, and for energy use see the watt-hour calculator.

📐 Formula

I  =  P / V   (DC)    I  =  P / ( V × PF )   (1-phase AC)    I  =  P / ( √3 × VLL × PF )   (3-phase AC)
I = current in amperes (A); for three-phase this is the line current
P = real power in watts (W); multiply kilowatts by 1000
V = voltage in volts; VLL is the line-to-line voltage for three-phase
PF = power factor, real power divided by apparent power (between 0 and 1)
√3 = 1.73205, the factor for balanced three-phase power
Apparent power: S = V × I for single-phase and S = √3 × VLL × I for three-phase; reactive power Q = √( S² − P² )
Delta winding current: Iphase = Iline / √3
Example: 1500 W at 12 V DC gives 125 A

📖 How to Use This Calculator

Steps

1
Choose the supply. Pick DC for batteries and low voltage supplies, Single-phase AC for household circuits, or Three-phase AC for balanced industrial loads.
2
Enter power, voltage and power factor. Type the power in watts or kilowatts and the voltage. For AC also enter the power factor; for three-phase use the line-to-line voltage.
3
Read the current and the comparison. The main box gives the current in amps. The other boxes give the apparent power and the delta winding current, and the table and chart show the current at other voltages.

💡 Example Calculations

Example 1 — 1500 W Inverter on a 12 V Battery

DC, P = 1500 W, V = 12 V

1
I = P / V = 1500 / 12
2
I = 125 A, which is 125,000 mA
3
At 24 V the same power would draw only 62.5 A, so doubling the battery voltage halves the current
Current = 125 A
Try this example →

Example 2 — 2.3 kW Kettle on 230 V

Single-phase AC, P = 2.3 kW, V = 230 V, PF = 1 (resistive heater)

1
P = 2.3 × 1000 = 2300 W
2
I = 2300 / ( 230 × 1 ) = 10 A
3
The apparent power is 2300 VA and the reactive power is 0, because a resistive load has a power factor of 1
Current = 10 A
Try this example →

Example 3 — 1500 W Motor Load with a Lagging Power Factor

Single-phase AC, P = 1500 W, V = 230 V, PF = 0.8 (illustrative)

1
I = 1500 / ( 230 × 0.8 ) = 1500 / 184 = 8.152 A
2
At PF = 1 the same load would draw 1500 / 230 = 6.522 A
3
Apparent power S = 230 × 8.152 = 1875 VA and reactive power Q = √( 1875² − 1500² ) = 1125 var
Current = 8.1522 A, apparent power = 1875 VA
Try this example →

Example 4 — 15 kW Three-phase Load at 400 V

Three-phase AC, P = 15 kW, VLL = 400 V, PF = 0.85 (illustrative)

1
P = 15,000 W and √3 × 400 × 0.85 = 588.9
2
I = 15,000 / 588.9 = 25.47 A in each line
3
Apparent power S = √3 × 400 × 25.47 = 17,647 VA, and in a delta connection each winding carries 25.47 / √3 = 14.71 A
Line current = 25.471 A, delta winding current = 14.706 A
Try this example →

Example 5 — 1800 W Heater on 120 V

Single-phase AC, P = 1800 W, V = 120 V, PF = 1

1
I = 1800 / ( 120 × 1 )
2
I = 15 A
3
The same heater on 230 V would draw only 7.83 A, which shows why higher voltage supplies carry more power on the same size of cable
Current = 15 A
Try this example →

❓ Frequently Asked Questions

How do you convert watts to amps?+
Divide the power in watts by the voltage: I = P / V for DC. For single-phase AC also divide by the power factor, I = P / (V x PF). A 1500 W load on 230 V with a power factor of 1 draws 1500 / 230 = 6.52 A.
Can you convert watts to amps without knowing the voltage?+
No. A watt is a rate of energy and an amp is a flow of charge, so the voltage links them. The same 1000 W is 83.3 A at 12 V, 8.33 A at 120 V and 4.35 A at 230 V.
What is the formula for watts to amps in single-phase AC?+
I = P / (V x PF), where PF is the power factor. With 1500 W, 230 V and PF 0.8 the current is 1500 / (230 x 0.8) = 8.15 A, and the apparent power is 1875 VA.
What is the formula for watts to amps in three-phase?+
For a balanced load with line-to-line voltage V, I = P / (sqrt(3) x V x PF). A 15 kW load at 400 V and PF 0.85 draws 15000 / (1.732 x 400 x 0.85) = 25.47 A in each line.
How many amps is 1000 watts?+
It depends on the voltage: about 83.3 A at 12 V DC, 8.33 A at 120 V, 4.35 A at 230 V, and 1.44 A per line in a 400 V three-phase system at unity power factor. Use the comparison table in the calculator to see them side by side.
How many amps is 1500 watts at 120 volts?+
At 120 V and unity power factor, 1500 W is 1500 / 120 = 12.5 A. A typical 1800 W heater on 120 V draws 15 A, which is why such devices usually need a dedicated circuit.
What power factor should I use if I do not know it?+
Resistive loads such as heaters and incandescent lamps have a power factor near 1. Motors, transformers and many electronic power supplies are lower. Check the nameplate or datasheet, and treat any default as an assumption.
What is the difference between line current and phase current?+
Line current flows in each supply conductor. In a wye connection the phase current equals the line current. In a delta connection each winding carries the line current divided by the square root of 3, which the calculator shows as the delta winding current.
What wire size do I need for a given current?+
The current sets the minimum conductor size, but the allowed size also depends on insulation temperature rating, cable length, installation method and local rules. Use the wire gauge calculator for an estimate and check the applicable electrical code.
Why does the current go down when the voltage goes up?+
For a fixed power, P = V x I means current falls in proportion as voltage rises. That is the reason long power lines use high voltage: lower current means smaller conductors and lower resistive losses.

How do you convert watts to amps?

Divide the power in watts by the voltage: I = P / V for DC. For single-phase AC also divide by the power factor, I = P / (V x PF). A 1500 W load on 230 V with a power factor of 1 draws 1500 / 230 = 6.52 A.

Can you convert watts to amps without knowing the voltage?

No. A watt is a rate of energy and an amp is a flow of charge, so the voltage links them. The same 1000 W is 83.3 A at 12 V, 8.33 A at 120 V and 4.35 A at 230 V.

What is the formula for watts to amps in single-phase AC?

I = P / (V x PF), where PF is the power factor. With 1500 W, 230 V and PF 0.8 the current is 1500 / (230 x 0.8) = 8.15 A, and the apparent power is 1875 VA.

What is the formula for watts to amps in three-phase?

For a balanced load with line-to-line voltage V, I = P / (sqrt(3) x V x PF). A 15 kW load at 400 V and PF 0.85 draws 15000 / (1.732 x 400 x 0.85) = 25.47 A in each line.

How many amps is 1000 watts?

It depends on the voltage: about 83.3 A at 12 V DC, 8.33 A at 120 V, 4.35 A at 230 V, and 1.44 A per line in a 400 V three-phase system at unity power factor. Use the comparison table in the calculator to see them side by side.

How many amps is 1500 watts at 120 volts?

At 120 V and unity power factor, 1500 W is 1500 / 120 = 12.5 A. A typical 1800 W heater on 120 V draws 15 A, which is why such devices usually need a dedicated circuit.

What power factor should I use if I do not know it?

Resistive loads such as heaters and incandescent lamps have a power factor near 1. Motors, transformers and many electronic power supplies are lower. Check the nameplate or datasheet, and treat any default as an assumption.

What is the difference between line current and phase current?

Line current flows in each supply conductor. In a wye connection the phase current equals the line current. In a delta connection each winding carries the line current divided by the square root of 3, which the calculator shows as the delta winding current.

What wire size do I need for a given current?

The current sets the minimum conductor size, but the allowed size also depends on insulation temperature rating, cable length, installation method and local rules. Use the wire gauge calculator for an estimate and check the applicable electrical code.

Why does the current go down when the voltage goes up?

For a fixed power, P = V x I means current falls in proportion as voltage rises. That is the reason long power lines use high voltage: lower current means smaller conductors and lower resistive losses.