Magnetic Permeability Calculator

Work out permeability, relative permeability, flux density and susceptibility, and see how a core multiplies inductance.

🧲 Magnetic Permeability Calculator
Material preset (illustrative values)
Relative permeability and field strength
Relative permeability μr
Field strength H (A/m)
Saturation flux density (optional)blank ignores saturation
T
Measured flux density and field strength
Flux density B (T)
Field strength H (A/m)
Core material preset (illustrative values)
Air-core inductance and core permeability
Air-core L0 (µH)
Core μr
Core path length and air gap
Path length (mm)
Air gap (mm)
Result
—
Result
—
Result
—
Result
—
Result
—
Result
—
Result
—
Result
—

Chart note: the B-H charts use a constant permeability, so they are straight lines. A real magnetic material saturates, and the optional saturation flux density flattens the blue line at that value, with the dashed grey line showing the unsaturated linear result.

🧲 What is Magnetic Permeability?

Magnetic permeability measures how readily a material lets a magnetic field form inside it. When a magnetizing field H, produced by currents in wires, is applied to a material, the material responds and a magnetic flux density B results. The two are related by B = μ H, and the constant μ is the permeability, in henries per metre. For empty space it has a fixed value μ0 of about 1.2566 × 10−6 H/m. For anything else it is usually quoted as a multiple of that value, the relative permeability μr = μ / μ0, which has no unit. Air has μr very close to 1, while soft iron alloys, ferrites and nickel-iron alloys such as mu-metal run from the thousands to the hundreds of thousands.

The idea is used wherever magnetic fields are shaped. A transformer or an inductor wraps its winding around a high-permeability core so that a small current produces a large flux and a large inductance. Magnetic shielding encloses a sensitive instrument in mu-metal so that stray fields prefer to travel through the shield rather than through the instrument. Electric motors, relays and electromagnets use iron paths to concentrate the field in the gap where it is needed. Materials scientists also use the susceptibility χ = μr − 1, which measures the magnetization M = χ H, to classify a material as diamagnetic, paramagnetic or ferromagnetic.

A few cautions apply. The permeability of a ferromagnet is not a constant: it depends on the field level, the history of the sample, the temperature and the frequency, and it falls toward μ0 when the material saturates. The presets in this calculator are rounded and illustrative, not data for any specific grade. A core with an air gap behaves very differently from a closed core, which is why this page includes a gapped-core mode. Permeability is also not the same as magnetic dipole moment, which describes a single magnet or loop, and which you can compute with the magnetic dipole moment calculator. For the field around a wire that creates H in the first place, use the magnetic field of a straight wire calculator. The inductance of a real winding is on the inductance of coil and solenoid calculator, and the stored energy of the field is on the energy density of fields calculator.

The calculator has three modes: B from a relative permeability and a field strength, the permeability and relative permeability from a measured B and H, and the inductance gain of a core with an optional air gap.

📐 Formula

μ = μ0 μr    B = μ H    χ = μr − 1    μeff = μr / (1 + μr g / l)
μ = permeability in H/m, and μ0 = 4π × 10−7 H/m (the 2018 CODATA value differs by about 5 parts in 1010).
μr = relative permeability, a pure number. χ = magnetic susceptibility, and the magnetization is M = χ H.
B = flux density in tesla (T) and H = magnetic field strength in amperes per metre (A/m).
Inductance: a core that fills the whole flux path multiplies the air-core inductance, L = μr L0.
Gapped core: g is the air gap and l the core path length, both in the same unit. Then L = μeff L0, ignoring fringing.
Example: μr = 5000 and H = 100 A/m give B = 4π × 10−7 × 5000 × 100 = 0.6283 T.

📖 How to Use This Calculator

Steps

1
Pick a mode. Use From mu_r when you know the material, From B and H when you have a measurement, and Core inductance to see how a core and an air gap change an inductor.
2
Choose a preset first, if you want one. Air, ferrite, iron and mu-metal fill the relative permeability with rounded illustrative values. Picking a preset overwrites the typed number, so choose it before editing.
3
Enter the field values. Give H, or B and H, or the inductance, path length and gap. Add a saturation flux density to see where a real core would flatten.
4
Read the results and the chart. The page shows B, μ, μr, susceptibility and the type of material, plus a B-H or gap chart with your point marked.

💡 Example Calculations

Example 1 — Flux Density in Soft Iron

An iron core with μr = 5000 (illustrative) in a field of H = 100 A/m

1
μ = 4π × 10−7 × 5000 = 0.006283 H/m.
2
B = μ H = 0.006283 × 100 = 0.6283 T, against 1.257e-4 T in vacuum.
3
χ = 5000 − 1 = 4999 and M = χ H = 4.999e+5 A/m.
B = 0.6283 T, μ = 0.006283 H/m
Try this example →

Example 2 — The Same Core Pushed Into Saturation

μr = 5000 at H = 1000 A/m with a saturation flux density of 2 T (illustrative)

1
The linear model gives B = 0.006283 × 1000 = 6.283 T.
2
That is above 2 T, so the core is saturated and the real B stays near 2 T.
3
The linear model stops being valid at H = 2 / 0.006283 = 318.3 A/m.
Linear B = 6.283 T, saturates above 318.3 A/m
Try this example →

Example 3 — Permeability from a Measurement

A sample shows B = 0.8 T at H = 200 A/m

1
μ = B / H = 0.8 / 200 = 0.004 H/m.
2
μr = 0.004 / (4π × 10−7) = 3183.
3
χ = 3182 and the magnetization is M = B / μ0 − H = 6.364e+5 A/m.
μ = 0.004 H/m, μr = 3183
Try this example →

Example 4 — A Gapped Ferrite Core

A 100 µH air-core coil on a core with μr = 2000 (illustrative), 100 mm path and a 0.5 mm gap

1
Without a gap, L = 2000 × 100 µH = 2.000e+5 µH, which is 200 mH.
2
μeff = 2000 / (1 + 2000 × 0.5 / 100) = 2000 / 11 = 181.8.
3
L = 181.8 × 100 µH = 18180 µH, so the gap removes 90.91 % of the inductance.
L with the gap = 18180 µH, μeff = 181.8
Try this example →

❓ Frequently Asked Questions

What is magnetic permeability?+
Magnetic permeability mu is the ratio of the magnetic flux density B in a material to the magnetizing field H that produces it, mu = B / H. It is measured in henries per metre (H/m) and tells how easily a material supports a magnetic field.
What is the value of the permeability of free space?+
mu0 = 4 pi x 10^-7 H/m, about 1.2566 x 10^-6 H/m. Since the 2019 SI redefinition it is measured rather than exactly defined, with a value of 1.25663706212e-6 H/m that differs from 4 pi x 10^-7 by about 5 parts in ten billion.
What is relative permeability?+
Relative permeability mu_r is the permeability of a material divided by that of free space, mu_r = mu / mu0. It is dimensionless: 1 for vacuum, slightly above 1 for air, and hundreds to hundreds of thousands for soft magnetic materials.
How do you calculate B from H?+
B = mu H = mu0 mu_r H. With mu_r = 5000 and H = 100 A/m, B = 4 pi x 10^-7 x 5000 x 100 = 0.628 T. This holds only while the material is below saturation.
What is magnetic susceptibility?+
Magnetic susceptibility chi is the ratio of the magnetization M to the field H, M = chi H, and chi = mu_r - 1. It is small for most materials and large for ferromagnets. Negative values indicate a diamagnetic material.
Do iron, ferrite and mu-metal have fixed permeabilities?+
No. Quoted values such as a few thousand for iron, a few thousand for some ferrites and tens of thousands for mu-metal are order of magnitude figures. The real value depends on the alloy, the heat treatment, the field level and the frequency, so use manufacturer data for design.
How does a core increase inductance?+
If a core fills the whole flux path, the inductance is multiplied by its relative permeability, L = mu_r L0. For a core with an air gap g in a path length l, the effective permeability is mu_r / (1 + mu_r g / l), so a gap reduces the gain a lot.
What is saturation in a B-H curve?+
Saturation is the region where nearly all magnetic domains are already aligned, so increasing H barely raises B. The slope of the B-H curve then approaches mu0. Iron alloys saturate near 1.5 to 2 tesla and ferrites at a few tenths of a tesla.
What is the difference between permeability and permittivity?+
Permeability describes the magnetic response of a material, B = mu H. Permittivity describes the electric response, D = epsilon E. They are linked by the speed of light, c = 1 / sqrt(mu0 epsilon0).
Can relative permeability be below 1?+
Yes, for diamagnetic materials such as copper, bismuth and water, relative permeability is slightly less than 1, for example 0.99999. The effect is tiny and the field is weakly repelled.
What is the difference between B and H?+
H is the field produced by the free currents, in A/m, and does not depend on the material. B is the resulting flux density in tesla, which includes the material's own magnetization: B = mu0 (H + M). In vacuum they differ only by the constant mu0.
Why does an air gap lower the inductance of a core?+
The gap has a much higher reluctance than the same length of high-permeability core, so even a short gap dominates the total reluctance. The effective permeability falls to roughly l / g when mu_r g / l is large, which is why designers use gaps to avoid saturation.

What is magnetic permeability?

Magnetic permeability mu is the ratio of the magnetic flux density B in a material to the magnetizing field H that produces it, mu = B / H. It is measured in henries per metre (H/m) and tells how easily a material supports a magnetic field.

What is the value of the permeability of free space?

mu0 = 4 pi x 10^-7 H/m, about 1.2566 x 10^-6 H/m. Since the 2019 SI redefinition it is measured rather than exactly defined, with a value of 1.25663706212e-6 H/m that differs from 4 pi x 10^-7 by about 5 parts in ten billion.

What is relative permeability?

Relative permeability mu_r is the permeability of a material divided by that of free space, mu_r = mu / mu0. It is dimensionless: 1 for vacuum, slightly above 1 for air, and hundreds to hundreds of thousands for soft magnetic materials.

How do you calculate B from H?

B = mu H = mu0 mu_r H. With mu_r = 5000 and H = 100 A/m, B = 4 pi x 10^-7 x 5000 x 100 = 0.628 T. This holds only while the material is below saturation.

What is magnetic susceptibility?

Magnetic susceptibility chi is the ratio of the magnetization M to the field H, M = chi H, and chi = mu_r - 1. It is small for most materials and large for ferromagnets. Negative values indicate a diamagnetic material.

Do iron, ferrite and mu-metal have fixed permeabilities?

No. Quoted values such as a few thousand for iron, a few thousand for some ferrites and tens of thousands for mu-metal are order of magnitude figures. The real value depends on the alloy, the heat treatment, the field level and the frequency, so use manufacturer data for design.

How does a core increase inductance?

If a core fills the whole flux path, the inductance is multiplied by its relative permeability, L = mu_r L0. For a core with an air gap g in a path length l, the effective permeability is mu_r / (1 + mu_r g / l), so a gap reduces the gain a lot.

What is saturation in a B-H curve?

Saturation is the region where nearly all magnetic domains are already aligned, so increasing H barely raises B. The slope of the B-H curve then approaches mu0. Iron alloys saturate near 1.5 to 2 tesla and ferrites at a few tenths of a tesla.

What is the difference between permeability and permittivity?

Permeability describes the magnetic response of a material, B = mu H. Permittivity describes the electric response, D = epsilon E. They are linked by the speed of light, c = 1 / sqrt(mu0 epsilon0).

Can relative permeability be below 1?

Yes, for diamagnetic materials such as copper, bismuth and water, relative permeability is slightly less than 1, for example 0.99999. The effect is tiny and the field is weakly repelled.