Lumen Calculator (Lumen to Lux to Candela)

Convert lumens to lux, candela and foot-candles, find the light at a distance, and work out how many lumens a room needs.

💡 Lumen Calculator (Lumen to Lux to Candela)
Luminous flux (Φ)
lm
Lit area (A)
Light reaching the surface
%
Luminous flux (Φ)
lm
Full beam angle (θ)
°
Intensity (I)
cd
Distance (d)
m
Angle of incidence (0 = surface faces the lamp)
°
Space type (illustrative levels)
Target illuminance
lx
Floor area
m²
Light reaching the surface
%
Output of one lamp
lm
Illuminance
—
Foot-candles
—
Lumens reaching surface
—
Area used
—

Luminous intensity
—
Solid angle
—
Share of full sphere
—
If spread in all directions
—
Lux at 1 m on axis
—

Illuminance
—
Foot-candles
—
Lux at 1 m
—
Lux at double distance
—

Lumens needed
—
Per square metre
—
Lamps needed
—
Reaching the surface
—

💡 What is a Lumen Calculator?

A lumen calculator converts between the three basic ways light is measured. The lumen (lm) is the unit of luminous flux, the total visible light a source puts out, weighted by how the human eye responds to different colours. The lux (lx) is the unit of illuminance, the lumens that land on each square metre of a surface, so 1 lux is 1 lumen per square metre. The candela (cd) is the unit of luminous intensity, the lumens sent into each steradian of solid angle in a particular direction, so 1 candela is 1 lumen per steradian. A lamp rated at 800 lumens has the same total output whether the light goes everywhere or is focused into a tight beam, but its candela and the lux it creates change a great deal.

The conversions matter in many everyday jobs. Homeowners compare bulbs sold by lumens with room lighting guidance given in lux. Photographers and filmmakers estimate how bright a light will be at a subject, and stage and architectural designers choose spotlight beam angles. Plant growers, safety inspectors and display designers all need the light level on a surface rather than the lamp's own output, which is why lumens alone are not enough. The foot-candle, one lumen per square foot, is still common in US lighting data and equals about 10.764 lux.

Three ideas explain most confusion. First, lumens do not tell you how bright a spot will look: the same 800 lumens gives 80 lux over 10 m² but also gives about 950 candela in a 60 degree beam, which lights a small patch very strongly. Second, light from a small source follows the inverse-square law, so doubling the distance cuts the lux to a quarter. Third, some of the light never reaches the work surface, because walls, shades and fixtures absorb it. The calculator therefore lets you set the percentage of light reaching the surface. The photon side of light is covered by the photon energy calculator, and its speed by the speed of light calculator.

This page has four modes. Lumens to lux spreads a flux evenly over an area in m² or ft². Lumens to candela turns a flux and a beam angle into intensity using the cone solid angle. Lux at distance applies E = I cos(angle) / d² for a small lamp. Lumens needed works backwards from a target lux and a room area to the lumens and number of lamps. The model assumes uniform light, a small point-like source and a flat surface, so use it for estimates and not for formal lighting design. The preset target levels are illustrative only.

📐 Formula

E  =  Φ ÷ A     I  =  Φ ÷ Ω     E  =  I cos α ÷ d²
E = illuminance in lux (lm/m²) and Φ = luminous flux in lumens, A = area in m²
I = luminous intensity in candela (lm/sr) and Ω = solid angle in steradians
Cone beam: Ω = 2π ( 1 − cos( θ / 2 ) ) for a full beam angle θ, and Ω = 4π sr (12.566) for all directions
Distance: E = I cos α / d², where α is the angle between the surface normal and the direction to the lamp
Foot-candles: 1 fc = 1 lm/ft² = 10.7639 lux, and 1 ft² = 0.09290304 m²
Lumens needed: Φ = E × A ÷ (share reaching the surface)
Example: 800 lm over 10 m² gives 800 / 10 = 80 lux

📖 How to Use This Calculator

Steps

1
Choose a mode. Pick Lumens to lux for a lit area, Lumens to candela for a beam, Lux at distance for a spotlight, or Lumens needed for a room.
2
Enter the light and the geometry. Type the luminous flux and area, the beam angle, the intensity and distance, or the target lux and room area. Set the percentage of light that reaches the surface if you want to allow for losses.
3
Read the result and the chart. Read lux and foot-candles, candela, or the lumens needed, and use the chart or table to see how the value changes with area, beam angle, distance or target level.

💡 Example Calculations

Example 1 — Lamp over a Small Room

800 lm spread evenly over 10 m², all of it reaching the surface

1
Light reaching the surface = 800 × 100 % = 800 lm
2
E = 800 / 10 = 80 lux
3
In foot-candles: 80 / 10.7639 = 7.432 fc
Illuminance = 80.00 lx (7.432 fc)
Try this example →

Example 2 — Lighting Data in Square Feet

1600 lm over 100 ft², all of it reaching the surface

1
Area in metres = 100 × 0.09290304 = 9.290 m²
2
E = 1600 / 9.290304 = 172.22 lux
3
In foot-candles: 1600 / 100 = 16.000 fc, since a foot-candle is already one lumen per square foot
Illuminance = 172.22 lx (16.000 fc)
Try this example →

Example 3 — Spot Bulb with a 60 Degree Beam

800 lm in a cone beam of 60° (assumed uniform)

1
Ω = 2π ( 1 − cos 30° ) = 2π × 0.13397 = 0.8418 sr, which is 6.70 % of a full sphere
2
I = 800 / 0.8418 = 950.36 cd
3
If the same 800 lumens went in all directions, I = 800 / 4π = 63.66 cd. The beam raises intensity about 15 times.
Luminous intensity = 950.36 cd
Try this example →

Example 4 — Narrow Spotlight

400 lm in a cone beam of 25° (assumed uniform)

1
Ω = 2π ( 1 − cos 12.5° ) = 0.1489 sr (1.19 % of a full sphere)
2
I = 400 / 0.14894 = 2685.71 cd
3
Spread in all directions the same lumens would be 400 / 4π = 31.83 cd, so the narrow beam is about 84 times more intense
Luminous intensity = 2685.71 cd
Try this example →

Example 5 — Spotlight at 2 Metres

I = 1000 cd, distance 2 m, surface facing the lamp

1
E = 1000 × cos 0° / 2² = 1000 / 4 = 250 lux
2
In foot-candles: 250 / 10.7639 = 23.226 fc
3
At 1 m the lux would be 1000.00 and at double the distance (4 m) it would be 1000 / 16 = 62.50 lux
Illuminance = 250.00 lx
Try this example →

Example 6 — Lamps for a 20 m² Room

Target 300 lux (illustrative), 20 m², 60 % of the light reaching the surface, 800 lm lamps

1
Lumens on the surface = 300 × 20 = 6000 lm
2
Lumens from the fixtures = 6000 / 0.60 = 10,000 lm, or 500 lm per m²
3
Lamps = 10,000 / 800 = 12.5, rounded up to 13 lamps
Lumens needed = 10,000 lm (13 lamps of 800 lm)
Try this example →

❓ Frequently Asked Questions

How do I convert lumens to lux?+
Divide the lumens by the area in square metres, lux = lumens / m2. 800 lumens spread evenly over 10 m2 gives 80 lux. Real rooms are not uniform, so this is an average, and any light that misses the surface lowers it.
How do I convert lumens to candela?+
Divide the lumens by the solid angle in steradians, candela = lumens / sr. For a cone beam of angle theta the solid angle is 2 pi (1 - cos(theta/2)). 800 lumens in a 60 degree beam gives about 950 cd.
What is the difference between lumens, lux and candela?+
Lumens measure total light output from a source. Lux is lumens per square metre arriving on a surface. Candela is lumens per steradian, the intensity in a particular direction. Output, arrival and direction are three separate quantities.
How many lumens do I need for a room?+
Multiply the target lux by the floor area in square metres, then divide by the share of light reaching the surface. 300 lux over 20 m2 with 60 percent reaching the surface needs 10,000 lumens. Target lux levels are design choices.
What is the inverse-square law for light?+
For a small source the illuminance on a surface facing it is E = I / d squared, where I is the intensity in candela and d the distance in metres. Doubling the distance gives a quarter of the illuminance.
How many lux is one candela?+
One candela produces one lux on a surface one metre away that faces it. At 2 m it is 0.25 lux, and at 0.5 m it is 4 lux. Tilting the surface multiplies the value by the cosine of the angle of incidence.
What is a foot-candle?+
A foot-candle is one lumen per square foot, equal to about 10.764 lux. 80 lux is 7.432 foot-candles. The calculator shows foot-candles next to lux for US-style lighting data.
Why does a narrow beam give more candela than a wide beam?+
Candela is lumens per unit of solid angle. With the same lumens in a smaller beam, each steradian carries more light. A 25 degree beam with 400 lumens is about 2686 cd, while the same lumens in all directions give 31.8 cd.
Can I convert lumens to watts?+
Not directly. The conversion depends on the luminous efficacy of the lamp in lumens per watt, which varies widely between lamp types. Divide the lumens by the efficacy printed on the lamp to estimate its electrical power.
What does the incidence angle do?+
It accounts for a surface that is tilted away from the light. Illuminance is multiplied by the cosine of the angle between the surface normal and the direction to the source, so 60 degrees halves the value and 90 degrees gives zero.
Why is my measured lux lower than the calculated value?+
The calculation assumes even light on a flat surface and no losses. A real lux meter reads the local value, which is higher under the lamp and lower at the edges, and walls, shades and dust absorb some light. Lower the share of light reaching the surface to model that.

How do I convert lumens to lux?

Divide the lumens by the area in square metres, lux = lumens / m2. 800 lumens spread evenly over 10 m2 gives 80 lux. Real rooms are not uniform, so this is an average, and any light that misses the surface lowers it.

How do I convert lumens to candela?

Divide the lumens by the solid angle in steradians, candela = lumens / sr. For a cone beam of angle theta the solid angle is 2 pi (1 - cos(theta/2)). 800 lumens in a 60 degree beam gives about 950 cd.

What is the difference between lumens, lux and candela?

Lumens measure total light output from a source. Lux is lumens per square metre arriving on a surface. Candela is lumens per steradian, the intensity in a particular direction. Output, arrival and direction are three separate quantities.

How many lumens do I need for a room?

Multiply the target lux by the floor area in square metres, then divide by the share of light reaching the surface. 300 lux over 20 m2 with 60 percent reaching the surface needs 10,000 lumens. Target lux levels are design choices.

What is the inverse-square law for light?

For a small source the illuminance on a surface facing it is E = I / d squared, where I is the intensity in candela and d the distance in metres. Doubling the distance gives a quarter of the illuminance.

How many lux is one candela?

One candela produces one lux on a surface one metre away that faces it. At 2 m it is 0.25 lux, and at 0.5 m it is 4 lux. Tilting the surface multiplies the value by the cosine of the angle of incidence.

What is a foot-candle?

A foot-candle is one lumen per square foot, equal to about 10.764 lux. 80 lux is 7.432 foot-candles. The calculator shows foot-candles next to lux for US-style lighting data.

Why does a narrow beam give more candela than a wide beam?

Candela is lumens per unit of solid angle. With the same lumens in a smaller beam, each steradian carries more light. A 25 degree beam with 400 lumens is about 2686 cd, while the same lumens in all directions give 31.8 cd.

Can I convert lumens to watts?

Not directly. The conversion depends on the luminous efficacy of the lamp in lumens per watt, which varies widely between lamp types. Divide the lumens by the efficacy printed on the lamp to estimate its electrical power.

What does the incidence angle do?

It accounts for a surface that is tilted away from the light. Illuminance is multiplied by the cosine of the angle between the surface normal and the direction to the source, so 60 degrees halves the value and 90 degrees gives zero.