Knudsen Number Calculator

Find the mean free path of a gas and the Knudsen number of a channel, pipe or vacuum chamber to see whether the flow is continuum, slip, transition or free molecular.

💨 Knudsen Number Calculator

Finds Kn = λ / L for your gas, temperature, pressure and length, and charts Kn against pressure.

Lists the pressure and the length at which the flow crosses Kn = 0.01, 0.1 and 10, and charts Kn against length.

Gas (illustrative diameters)
Molecule diameter (d)
nm
Temperature (T)
Pressure (p)
Characteristic length (L)
Knudsen number Kn
—
Flow regime
—
Mean free path λ
—
λ in nanometres
—
Number density n = p / kT
—
Temperature used
—

Pressure for Kn = 0.01
—
Pressure for Kn = 10
—
Length for Kn = 0.01
—
Length for Kn = 10
—

💨 What is the Knudsen Number?

The Knudsen number, Kn, is the ratio of the mean free path of the gas molecules to a characteristic length of the flow: Kn = λ / L. The mean free path is the average distance a molecule travels between collisions with other molecules. When it is tiny compared with the size of the pipe, channel or body, the gas behaves as a continuous fluid and the usual equations of fluid mechanics work. When the mean free path becomes comparable to the size, the gas stops acting like a continuum, because molecules strike the walls about as often as they strike each other. The Knudsen number is therefore the dimensionless measure of how rarefied a flow is.

It matters wherever gases are confined to small sizes or low pressures. Vacuum engineers use it to decide whether pumping lines are in viscous or molecular flow. Microfluidics and MEMS designers use it for gas flow in microchannels, where slip at the wall changes the flow rate. Aerospace engineers use it for spacecraft re-entering the thin upper atmosphere, and semiconductor and thin film engineers use it for low pressure deposition chambers. Aerosol scientists use a particle Knudsen number to choose slip corrections for small particles. In each case Kn tells you whether the standard Navier-Stokes model is allowed.

A few distinctions are worth knowing. The regime boundaries are a convention: this page uses continuum below 0.01, slip from 0.01 to 0.1, transition from 0.1 to 10 and free molecular above 10, but other sources use slightly different cut-offs. The characteristic length is a choice, so two papers can quote different Kn for the same flow. And the mean free path depends strongly on the gas: it scales with temperature divided by pressure and by the molecule diameter squared. This page is about gas rarefaction, while the Reynolds number calculator measures the balance of inertia and viscosity and the Mach number calculator measures speed against sound speed.

This calculator gives the mean free path, Kn and the regime in one step. A second tab lists the pressures and lengths where the regime changes, and log-log charts show where your case sits.

📐 Formula

Kn  =  λ / L   with   λ = kB T / ( √2 π d² p )
Kn = Knudsen number (dimensionless)
λ = mean free path (m) for hard-sphere molecules
L = characteristic length of the flow (m), such as channel height, pipe diameter or body size
kB = Boltzmann constant, 1.380649 × 10-23 J/K
T = absolute temperature (K), p = pressure (Pa), d = effective molecule diameter (m); the presets are illustrative rounded values (air 0.37 nm, helium 0.22 nm)
Number density: n = p / (kB T)
Regimes (common convention): Kn < 0.01 continuum; 0.01 to 0.1 slip; 0.1 to 10 transition; above 10 free molecular
Boundary pressures and lengths: pb = p Kn / Knb at fixed L, and Lb = λ / Knb at fixed p
Example: air at 293.15 K and 101325 Pa with d = 0.37 nm gives λ = 65.67 nm, so in a 1 µm channel Kn = 0.0657

📖 How to Use This Calculator

Steps

1
Choose a gas and conditions. Pick a gas preset (or type a molecule diameter in nm), then enter the temperature and pressure with their units. The unit selectors only tell the calculator how to read the number you typed.
2
Enter the characteristic length. Type the channel width, pipe diameter, gap or body size with its unit, such as micrometres for a microchannel or metres for a vacuum chamber.
3
Read Kn, the regime and the chart. Read the mean free path, the Knudsen number and the flow regime, use the Regime boundaries tab for the pressures and lengths where the regime changes, and check the log-log chart.

💡 Example Calculations

Example 1 — Air in a One Micron Channel

Air (d = 0.37 nm) at 20 °C and 101325 Pa in a channel 1 µm across

1
T = 293.15 K, d² = (0.37e-9)² = 1.369e-19 m², and √2 π d² p = 6.163e-14
2
λ = 1.380649e-23 × 293.15 / 6.163e-14 = 65.67 nm
3
Kn = 65.67 nm / 1000 nm = 0.0657, which is in the slip regime (0.01 to 0.1). The number density is 2.503e25 per m³.
Kn = 0.0657 (Slip)
Try this example →

Example 2 — A High Vacuum Chamber

Air at 20 °C and 0.001 Pa in a chamber 0.3 m across

1
Pressure is 101325 times lower than atmospheric, so λ = 65.67 nm × 101325 / 0.001 = 6.654 m
2
Kn = 6.654 / 0.3 = 22.18
3
Kn is well above 10, so the flow is free molecular: molecules fly from wall to wall without colliding. For this chamber Kn = 10 is reached at 2.218e-3 Pa, and the flow is free molecular at any lower pressure.
Kn = 22.18 (Free molecular)
Try this example →

Example 3 — Helium in a 100 nm Channel

Helium (d = 0.22 nm) at 20 °C and 1 atm in a nanochannel 100 nm across

1
d² = 4.84e-20 m² and p = 101325 Pa, so √2 π d² p = 2.179e-14
2
λ = 1.380649e-23 × 293.15 / 2.179e-14 = 185.76 nm, nearly 3 times the value for air
3
Kn = 185.76 / 100 = 1.8576, in the transition regime (0.1 to 10), so kinetic models are needed. The diameter 0.22 nm is an illustrative value.
Kn = 1.8576 (Transition)
Try this example →

Example 4 — Ordinary Air in a One Centimetre Gap

Air at 25 °C and 101.325 kPa in a gap 1 mm across

1
T = 298.15 K, so λ = 65.67 nm × 298.15 / 293.15 = 66.79 nm
2
Kn = 66.79e-9 / 1e-3 = 6.679e-5
3
Kn is far below 0.01, so the flow is continuum. The no-slip Navier-Stokes equations hold, which is why everyday duct and pipe flow never needs a rarefaction correction.
Kn = 6.679e-5 (Continuum)
Try this example →

Example 5 — Regime Boundaries for the Microchannel

Air at 20 °C and 101325 Pa with L = 1 µm: where do the regimes change?

1
With λ = 65.67 nm and Kn = 0.0657, the pressure for any boundary is pb = 101325 × 0.0657 / Knb
2
Kn = 0.01 at 6.654e+5 Pa, Kn = 0.1 at 6.654e+4 Pa and Kn = 10 at 6.654e+2 Pa for the 1 µm channel
3
At 101325 Pa, the flow is continuum for passages above λ / 0.01 = 6.567 µm, and free molecular below λ / 10 = 6.57 nm.
Kn = 0.01 at 6.654e+5 Pa, Kn = 10 at 6.654e+2 Pa
Try this example →

Example 6 — Argon at One Torr in a 10 mm Tube

Argon (d = 0.36 nm) at 300 K and 1 Torr (133.32 Pa) in a tube 10 mm across

1
λ = 1.380649e-23 × 300 / ( √2 π × (0.36e-9)² × 133.32 ) = 5.3955e-5 m = 53.955 µm
2
Kn = 53.955e-6 / 0.01 = 0.0054, so the flow is continuum (just under 0.01)
3
The Kn = 0.01 boundary for this tube is at 133.32 × 0.0054 / 0.01 = 7.193e+1 Pa; below about 72 Pa, slip effects begin. The argon diameter is an illustrative value.
Kn = 0.0054 (Continuum), Kn = 0.01 at 7.193e+1 Pa
Try this example →

❓ Frequently Asked Questions

What is the Knudsen number?+
The Knudsen number is the ratio of the molecular mean free path lambda to a characteristic length L of the flow: Kn = lambda / L. It measures how rarefied a gas is relative to the size of the passage or body it flows around.
How do you calculate the mean free path of a gas?+
For hard-sphere molecules, lambda = k T / (sqrt(2) pi d squared p), where k is Boltzmann's constant, T the temperature, d the molecular diameter and p the pressure. Air at 20 C and 101325 Pa with d = 0.37 nm gives about 65.7 nm.
What are the Knudsen number flow regimes?+
A common convention is continuum for Kn below 0.01, slip flow from 0.01 to 0.1, transition flow from 0.1 to 10, and free molecular flow above 10. The boundaries vary somewhat between textbooks and application areas.
What is the mean free path of air at atmospheric pressure?+
About 66 to 68 nanometres at room temperature and 101325 Pa. With d = 0.37 nm and 20 C this calculator returns 65.67 nm. It grows in inverse proportion to pressure and in proportion to absolute temperature.
At what pressure does a vacuum chamber become free molecular?+
When the mean free path exceeds about ten times the chamber size. For air in a 0.3 m chamber at 20 C, Kn reaches 10 near 2.2e-3 Pa, so at 1e-3 Pa (Kn = 22) the flow is free molecular.
What is slip flow and when does it matter?+
In slip flow (Kn about 0.01 to 0.1) gas next to a wall no longer has zero velocity, so the no-slip condition fails. It matters in microchannels, MEMS devices, thin films and some vacuum lines. Air in a 1 micron channel at 1 atm has Kn = 0.066.
How does temperature change the Knudsen number?+
Through the mean free path, which is proportional to absolute temperature at fixed pressure. Heating air from 293 K to 586 K at constant pressure doubles lambda and doubles Kn.
Why does the Knudsen number depend on gas type?+
Because lambda depends on molecular diameter squared. Helium (small molecules, d about 0.22 nm) has a mean free path of about 186 nm at 1 atm, nearly three times that of air, so it reaches the transition regime in a 100 nm channel.
How is Kn different from the Reynolds and Mach numbers?+
Reynolds number compares inertia with viscosity, Mach number compares speed with the speed of sound, and Knudsen number compares molecular scale with flow scale. They are related for gases: Kn is proportional to Mach divided by Reynolds.
Can I use this for liquids?+
No. The mean free path formula is for dilute gases. Liquids are dense and do not have a molecular mean free path of this kind, so the Knudsen number concept does not apply in this form.
What characteristic length should I use?+
Use the smallest physical length that limits the flow: the diameter or height of a channel, the radius of a tube, or the size of a particle or body. For non-circular channels use the hydraulic diameter, and report the choice with your Kn.

What is the Knudsen number?

The Knudsen number is the ratio of the molecular mean free path lambda to a characteristic length L of the flow: Kn = lambda / L. It measures how rarefied a gas is relative to the size of the passage or body it flows around.

How do you calculate the mean free path of a gas?

For hard-sphere molecules, lambda = k T / (sqrt(2) pi d squared p), where k is Boltzmann's constant, T the temperature, d the molecular diameter and p the pressure. Air at 20 C and 101325 Pa with d = 0.37 nm gives about 65.7 nm.

What are the Knudsen number flow regimes?

A common convention is continuum for Kn below 0.01, slip flow from 0.01 to 0.1, transition flow from 0.1 to 10, and free molecular flow above 10. The boundaries vary somewhat between textbooks and application areas.

What is the mean free path of air at atmospheric pressure?

About 66 to 68 nanometres at room temperature and 101325 Pa. With d = 0.37 nm and 20 C this calculator returns 65.67 nm. It grows in inverse proportion to pressure and in proportion to absolute temperature.

At what pressure does a vacuum chamber become free molecular?

When the mean free path exceeds about ten times the chamber size. For air in a 0.3 m chamber at 20 C, Kn reaches 10 near 2.2e-3 Pa, so at 1e-3 Pa (Kn = 22) the flow is free molecular.

What is slip flow and when does it matter?

In slip flow (Kn about 0.01 to 0.1) gas next to a wall no longer has zero velocity, so the no-slip condition fails. It matters in microchannels, MEMS devices, thin films and some vacuum lines. Air in a 1 micron channel at 1 atm has Kn = 0.066.

How does temperature change the Knudsen number?

Through the mean free path, which is proportional to absolute temperature at fixed pressure. Heating air from 293 K to 586 K at constant pressure doubles lambda and doubles Kn.

Why does the Knudsen number depend on gas type?

Because lambda depends on molecular diameter squared. Helium (small molecules, d about 0.22 nm) has a mean free path of about 186 nm at 1 atm, nearly three times that of air, so it reaches the transition regime in a 100 nm channel.

How is Kn different from the Reynolds and Mach numbers?

Reynolds number compares inertia with viscosity, Mach number compares speed with the speed of sound, and Knudsen number compares molecular scale with flow scale. They are related for gases: Kn is proportional to Mach divided by Reynolds.

Can I use this for liquids?

No. The mean free path formula is for dilute gases. Liquids are dense and do not have a molecular mean free path of this kind, so the Knudsen number concept does not apply in this form.

What characteristic length should I use?

Use the smallest physical length that limits the flow: the diameter or height of a channel, the radius of a tube, or the size of a particle or body. For non-circular channels use the hydraulic diameter, and report the choice with your Kn.