dB Calculator

Convert ratios to decibels and back, translate dBm, dBW, dBV and dBu, add levels and see the whole curve.

📊 dB Calculator
Type of quantity
Ratio (output / input)
×
Type of quantity
Level difference
dB
Starting unit
Value and loadthe load links power to voltage
Value in the unit above
Load impedance (ohm)
Levels in dBuncorrelated sources, blank is ignored
Level 1 (dB)
Level 2 (dB)
Level 3 (dB)
Level 4 (dB)
Type of quantity
Percent changenegative for a decrease
%
Level in dB
—
If read as the other type
—
Percent change
—
Reciprocal ratio
—

Linear ratio (chosen type)
—
As a power ratio
—
As an amplitude ratio
—
Percent change (chosen type)
—

Level in dBm
—
Level in dBW
—
Power
—
Voltage across the load
—
Level in dBV
—
Level in dBu
—

Combined level (incoherent)
—
Worst case (in phase)
—
Loudest single level
—
Added over the loudest
—
Levels used
—

Change in dB
—
Ratio new / old
—
If read as the other type
—

Chart: the curve shows the ratio for every dB value (ratio modes) or the dB added to the louder of two sources as the gap between them grows (Add levels). The green dashed line and dot mark your current value.

📊 What is a dB Calculator?

A dB calculator converts between ordinary linear ratios and decibels, the logarithmic unit used to compare two powers or two field amplitudes. The decibel is one tenth of a bel. For power the level difference is 10 log10 of the ratio, and for an amplitude quantity such as voltage, current or sound pressure it is 20 log10 of the ratio. Because the scale is logarithmic, a huge range of values fits in a short list of numbers: a factor of one million in power is only 60 dB, and a factor of one billionth is -90 dB. Multiplication of ratios becomes addition of decibels, which is why engineers cascade amplifiers, filters and cables by simply adding numbers.

This page is the general converter. It handles the five jobs people most often search for. Ratio to dB and dB to ratio are the basic pair. Absolute levels translates between dBm, dBW, dBV, dBu, milliwatts, watts and volts using a load impedance you choose. Add levels combines several noise or sound sources the physically correct way, by adding their powers rather than their decibel numbers. Percent change turns a statement such as a 20 percent loss of power into decibels. If you need the gain of one amplifier or a whole chain of stages, with pads and cable losses, use the dB gain calculator, which builds on the same formulas.

Decibels are used across physics and engineering: sound levels and acoustic transmission loss, radio link budgets, antenna and amplifier gain, audio mixing desks, optical fibre loss, and signal to noise ratios. The most common mistakes are using 10 log for a voltage ratio, adding decibel values of independent sources directly, and forgetting that dBm is a power level while dBu is a voltage level. A plain dB figure is always a ratio. It only becomes an absolute level once a reference is attached, such as 1 mW for dBm. The related signal to noise ratio calculator and the link budget calculator both rely on these conversions.

The chart makes the scale tangible. Both the power and the amplitude ratio curves climb by a factor of ten every 10 dB and 20 dB respectively, which is a straight line on a logarithmic axis, and the marker shows where your number sits. In Add levels mode the chart shows the well known rule that a source more than about 10 dB below another adds less than 0.41 dB, so the quieter one can usually be ignored.

📐 Formula

LP = 10 log10(P2 / P1)    LA = 20 log10(A2 / A1)    Lsum = 10 log10(Σ 10Li/10)
P2 / P1 = power (or intensity) ratio. A2 / A1 = amplitude ratio of a field quantity such as voltage, current or sound pressure. The 20 log form follows because power is proportional to amplitude squared.
Inverse: power ratio = 10dB/10 and amplitude ratio = 10dB/20.
dBm: 10 log10(P / 1 mW). dBW: 10 log10(P / 1 W) = dBm − 30.
dBV: 20 log10(V / 1 V). dBu: 20 log10(V / 0.7746 V), where 0.7746 V = √(0.6) is the voltage giving 1 mW in 600 ohm. So dBu = dBV + 2.218.
Power and voltage: P = V2 / R, with V in volts rms and R the load in ohms.
Percent change: ratio = 1 + p / 100, then convert the ratio with the 10 log or 20 log formula.
Example: a power ratio of 2 gives 10 log10(2) = 3.01 dB, while an amplitude ratio of 2 gives 6.02 dB.

📖 How to Use This Calculator

Steps

1
Choose a conversion. Use the tabs: Ratio to dB, dB to ratio, Absolute levels, Add levels or Percent change.
2
Select the type. Pick power (10 log10) or amplitude (20 log10), or in Absolute levels pick the unit you are starting from. The select never alters the number you typed.
3
Enter the value. Type the ratio, the dB figure, the level and load impedance, up to four levels to add, or the percent change. Leave unused level boxes blank.
4
Read the results. The conversions and a short worked sentence update immediately, and the chart marks your value on the curve.

💡 Example Calculations

Example 1 — Doubling the Power

A transmitter doubles its output power, a power ratio of 2

1
dB = 10 × log10(2) = 10 × 0.30103 = 3.01 dB.
2
If the same 2 were an amplitude ratio the answer would be 20 × 0.30103 = 6.02 dB.
3
Percent change = (2 − 1) × 100 = 100.00 % and the reciprocal ratio 1/2 is −3.01 dB.
Power ratio 2 = 3.01 dB
Try this example →

Example 2 — Halving a Voltage

A resistive divider halves the signal voltage, an amplitude ratio of 0.5

1
dB = 20 × log10(0.5) = 20 × (−0.30103) = −6.02 dB.
2
Percent change = (0.5 − 1) × 100 = −50.00 %.
3
Read as a power ratio the same 0.5 would be −3.01 dB, which is the usual confusion between half the voltage and half the power.
Voltage ratio 0.5 = −6.02 dB
Try this example →

Example 3 — 20 dB of Voltage Gain

An amplifier is specified at 20 dB and the quantity is a voltage

1
Amplitude ratio = 1020/20 = 10.
2
Power ratio = 1020/10 = 100.
3
Percent change of the voltage = (10 − 1) × 100 = 900.00 %.
20 dB = voltage x10, power x100
Try this example →

Example 4 — 30 dBm Into 50 Ohm

A 30 dBm transmitter output into a 50 ohm load

1
P = 1 mW × 1030/10 = 1000 mW = 1 W, so the level is 0.00 dBW.
2
V = √(P × R) = √(1 × 50) = 7.0711 V rms.
3
dBV = 20 log10(7.0711) = 16.99 dBV and dBu = 20 log10(7.0711 / 0.7746) = 19.21 dBu.
30 dBm = 1 W = 7.0711 V = 16.99 dBV = 19.21 dBu
Try this example →

Example 5 — Four Noise Sources

Four uncorrelated sources measure 85, 82, 78 and 70 dB at a listener

1
Sum of powers (relative to the reference) = 108.5 + 108.2 + 107.8 + 107.0.
2
L = 10 log10(sum) = 87.39 dB, which is 2.39 dB above the loudest source (85 dB).
3
If the four signals were identical and in phase the amplitudes would add instead, giving the worst case of 92.36 dB.
Combined level = 87.39 dB
Try this example →

Example 6 — A 20 Percent Power Loss

A cable delivers 20 percent less power than it receives

1
Ratio new / old = 1 + (−20 / 100) = 0.8.
2
dB = 10 × log10(0.8) = −0.97 dB.
3
If the 20 percent were an amplitude change the loss would be 20 × log10(0.8) = −1.94 dB.
20 percent power loss = −0.97 dB
Try this example →

❓ Frequently Asked Questions

How do you convert a ratio to dB?+
For a power ratio use dB = 10 x log10(P2 / P1). For an amplitude ratio such as voltage, current or sound pressure use dB = 20 x log10(A2 / A1). A power ratio of 2 is 3.01 dB and an amplitude ratio of 2 is 6.02 dB.
How do you convert dB to a ratio?+
Invert the formula. A power ratio is 10 raised to the power dB / 10 and an amplitude ratio is 10 raised to the power dB / 20. For 20 dB that gives a power ratio of 100 and an amplitude ratio of 10.
Why is it 10 log for power and 20 log for voltage?+
Power is proportional to the square of voltage across a fixed resistance. Because log(V squared) equals 2 log(V), a voltage ratio is multiplied by 20 instead of 10 to give the same decibel value as the power ratio it produces.
What is dBm and how do I convert it to watts?+
dBm is power relative to 1 milliwatt. Power in mW is 10 raised to dBm / 10. So 0 dBm is 1 mW, 20 dBm is 100 mW and 30 dBm is 1 W. The calculator also shows dBW, which is dBm minus 30.
What is the difference between dBV and dBu?+
dBV is relative to 1 V rms. dBu is relative to 0.7746 V rms, the voltage that gives 1 mW in 600 ohms. Because the references differ, dBu is 2.22 dB higher than dBV for the same voltage, so +4 dBu equals about +1.78 dBV.
How do you add decibels?+
Do not add them directly. Convert each level to power with 10 raised to dB / 10, add the powers, then take 10 log10 of the sum. Two equal sources add 3.01 dB, four equal sources add 6.02 dB and ten equal sources add 10 dB.
What is 3 dB in percent?+
A 3 dB change is a power factor of 1.995, nearly double, which is a 99.5 percent increase. A -3 dB change leaves 50.1 percent of the power, so about half is lost. In amplitude 3 dB is a factor of 1.413.
How many dB is a 10 percent change?+
A 10 percent power increase is 10 x log10(1.1) = 0.41 dB. A 10 percent power decrease is 10 x log10(0.9) = -0.46 dB. The same percentages applied to an amplitude give twice those dB values.
Can a decibel value be negative?+
Yes. A negative decibel value means the output is smaller than the reference, a ratio below 1. -10 dB is a tenth of the power and -6 dB is about a half of the amplitude. 0 dB means no change.
Is dB an absolute unit?+
Plain dB is a ratio and has no reference. Absolute levels add a reference letter, such as dBm for 1 mW, dBW for 1 W, dBV for 1 V and dBu for 0.7746 V. Only absolute levels can be converted to watts or volts.
Why does the dBm to dBV conversion depend on impedance?+
dBm measures power and dBV measures voltage, and the two are linked by P = V squared / R. The same 0 dBm is 0.2236 V in 50 ohms (-13.01 dBV) but 0.7746 V in 600 ohms (-2.22 dBV). Only the dBm to dBW step is independent of the load.

How do you convert a ratio to dB?

For a power ratio use dB = 10 x log10(P2 / P1). For an amplitude ratio such as voltage, current or sound pressure use dB = 20 x log10(A2 / A1). A power ratio of 2 is 3.01 dB and an amplitude ratio of 2 is 6.02 dB.

How do you convert dB to a ratio?

Invert the formula. A power ratio is 10 raised to the power dB / 10 and an amplitude ratio is 10 raised to the power dB / 20. For 20 dB that gives a power ratio of 100 and an amplitude ratio of 10.

Why is it 10 log for power and 20 log for voltage?

Power is proportional to the square of voltage across a fixed resistance. Because log(V squared) equals 2 log(V), a voltage ratio is multiplied by 20 instead of 10 to give the same decibel value as the power ratio it produces.

What is dBm and how do I convert it to watts?

dBm is power relative to 1 milliwatt. Power in mW is 10 raised to dBm / 10. So 0 dBm is 1 mW, 20 dBm is 100 mW and 30 dBm is 1 W. The calculator also shows dBW, which is dBm minus 30.

What is the difference between dBV and dBu?

dBV is relative to 1 V rms. dBu is relative to 0.7746 V rms, the voltage that gives 1 mW in 600 ohms. Because the references differ, dBu is 2.22 dB higher than dBV for the same voltage, so +4 dBu equals about +1.78 dBV.

How do you add decibels?

Do not add them directly. Convert each level to power with 10 raised to dB / 10, add the powers, then take 10 log10 of the sum. Two equal sources add 3.01 dB, four equal sources add 6.02 dB and ten equal sources add 10 dB.

What is 3 dB in percent?

A 3 dB change is a power factor of 1.995, nearly double, which is a 99.5 percent increase. A -3 dB change leaves 50.1 percent of the power, so about half is lost. In amplitude 3 dB is a factor of 1.413.

How many dB is a 10 percent change?

A 10 percent power increase is 10 x log10(1.1) = 0.41 dB. A 10 percent power decrease is 10 x log10(0.9) = -0.46 dB. The same percentages applied to an amplitude give twice those dB values.

Can a decibel value be negative?

Yes. A negative decibel value means the output is smaller than the reference, a ratio below 1. -10 dB is a tenth of the power and -6 dB is about a half of the amplitude. 0 dB means no change.

Is dB an absolute unit?

Plain dB is a ratio and has no reference. Absolute levels add a reference letter, such as dBm for 1 mW, dBW for 1 W, dBV for 1 V and dBu for 0.7746 V. Only absolute levels can be converted to watts or volts.